K-edge digital subtraction arthrography of the painful hip prosthesis: a feasibility study.

作者信息

Kelcz F, Peppler W W, Mistretta C A, DeSmet A, McBeath A A

机构信息

Department of Radiology, University of Wisconsin Hospitals and Clinics, Madison 53792.

出版信息

AJR Am J Roentgenol. 1990 Nov;155(5):1053-8. doi: 10.2214/ajr.155.5.2120935.

DOI:10.2214/ajr.155.5.2120935
PMID:2120935
Abstract

K-edge energy subtraction radiography is a method for detecting the presence of iodinated contrast material by subtracting two digital radiographs produced by X-ray beams with energies above and below the iodine K edge. We performed a feasibility study on the application of K-edge energy digital subtraction arthrography (KEDSA) to painful hip prostheses. During arthrography, loosening of the prosthesis is implied if contrast material is seen dissecting around the prosthesis, an often difficult detection task because of adjacent prosthesis metal or cement. In conventional arthrography a preliminary mask image is thus used from which films obtained after injection of iodinated contrast material are subtracted. Movement by the patient during this process may preclude subsequent subtraction. With KEDSA, since multiple image pairs may be obtained after the injection of contrast material, the problem of patient motion is virtually eliminated. A conventional X-ray tube operating between 55 and 65 kVp was alternately filtered by iodine and cerium filters to produce the KEDSA images. The apparatus was capable of producing a subtracted image within 3 sec. The technique was applied to phantoms and to six patients immediately after hip arthrography that had been positive for prosthesis loosening. Although of lower spatial resolution, the KEDSA images were, in all cases, positive for loosening in a pattern consistent with the conventional arthrographic images. KEDSA was shown to be successful in detecting extraarticular contrast material. During a single study, subtraction in various imaging planes as well as postexercise subtraction imaging can be accomplished-techniques not heretofore possible in routine subtraction arthrography.

摘要

相似文献

1
K-edge digital subtraction arthrography of the painful hip prosthesis: a feasibility study.
AJR Am J Roentgenol. 1990 Nov;155(5):1053-8. doi: 10.2214/ajr.155.5.2120935.
2
Arthrography of painful hips following arthroplasty: digital versus plain film subtraction.人工关节置换术后疼痛性髋关节造影:数字减影与普通X线片减影对比
Skeletal Radiol. 1991;20(6):403-7. doi: 10.1007/BF00191080.
3
Digital subtraction arthrography of hip joint prostheses.
Diagn Imaging Clin Med. 1986;55(4-5):228-32.
4
[The methods and place of digital subtraction arthrography of the hip in detecting endoprosthesis loosening].
Rofo. 1991 Sep;155(3):255-9. doi: 10.1055/s-2008-1033257.
5
The value of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip prostheses: a meta-analysis.
Eur J Radiol. 2005 Oct;56(1):113-9. doi: 10.1016/j.ejrad.2005.02.008.
6
The diagnostic value of digital subtraction arthrography and radionuclide arthrography in revision total hip arthroplasty.
Biomed Tech (Berl). 2004 Dec;49(12):351-5. doi: 10.1515/BMT.2004.065.
7
Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty.
Skeletal Radiol. 1996 May;25(4):357-63. doi: 10.1007/s002560050095.
8
The use of subtraction arthrography in total hip arthroplasties.
Rofo. 1986 Apr;144(4):440-6. doi: 10.1055/s-2008-1048819.
9
Nuclear arthrography: combined scintigraphic and radiographic procedure for diagnosis of total hip prosthesis loosening.核关节造影术:用于诊断全髋关节假体松动的闪烁扫描与放射照相联合检查方法。
J Nucl Med. 1996 Jan;37(1):62-70.
10
Digital arthrography in the evaluation of painful joint prostheses.
Invest Radiol. 1984 Sep-Oct;19(5):432-7. doi: 10.1097/00004424-198409000-00016.

引用本文的文献

1
Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE.光谱(多能量) CT 可区分 MICE 中的碘和钡造影剂。
Eur Radiol. 2010 Sep;20(9):2126-34. doi: 10.1007/s00330-010-1768-9. Epub 2010 Mar 23.