Effect of delay between erasure and image acquisition in CR.

作者信息

Al Khalifah Khaled H, Brindhaban Ajit

机构信息

Department of Radiologic Sciences, Kuwait University, Kuwait.

出版信息

Radiol Technol. 2011 Jan-Feb;82(3):214-8.

PMID:21209423
Abstract

OBJECTIVE

The effect of time delay between last erasure and image acquisition using computed radiography (CR) image plates (IPs) was investigated using an Agfa ADC Compact CR system.

METHOD

IPs of various sizes were erased by the IP processing cycle of the CR system. These IPs then were stored in their normal storage place for various durations, ranging from 0 hours to 168 hours. The IPs then were processed, and dark noise images were obtained. The dark noise in each plate was estimated by measuring the average pixel value in several places on the image. Statistical analysis was carried out using 1-way analysis of variance and Kruskal-Wallis testing for any significant differences in dark noise between time delays at P = .05. Regression analysis was carried out to test any relationship between dark noise and time delay.

RESULTS

Statistically significant (P < .05) increases in dark current were observed when the time delay increased, with increase greater than 40% for time delays more than 24 hours. In the short term (< 1 hour), a quadratic relationship was observed, and in the long term (> 24 hours) a linear relationship was observed between dark current and time delay.

CONCLUSION

Dark noise increases with time delay, and it is useful to erase the IP before image acquisition if time delays of more than 24 hours are experienced, such as over a weekend.

摘要

相似文献

1
Effect of delay between erasure and image acquisition in CR.
Radiol Technol. 2011 Jan-Feb;82(3):214-8.
2
Computed radiography simulation using the Monte Carlo code MCNPX.
Appl Radiat Isot. 2010 Sep;68(9):1662-70. doi: 10.1016/j.apradiso.2010.02.011. Epub 2010 Feb 25.
3
Exposure indicator degradation from CR plate processing delays.由于计算机X线摄影(CR)板处理延迟导致的曝光指示器退化。
Radiol Technol. 2009 May-Jun;80(5):401-9.
4
A sagittally focusing double-multilayer monochromator for ultrafast X-ray imaging applications.一种用于超快X射线成像应用的矢状聚焦双多层单色仪。
J Synchrotron Radiat. 2007 Jan;14(Pt 1):138-43. doi: 10.1107/S0909049506050205. Epub 2006 Dec 15.
5
Advances in computed radiography systems and their physical imaging characteristics.计算机X线摄影系统的进展及其物理成像特性。
Clin Radiol. 2007 Dec;62(12):1132-41. doi: 10.1016/j.crad.2007.07.009. Epub 2007 Sep 7.
6
Dual-energy computed tomographic scanners: principles, comparisons, and contrasts.双能计算机断层扫描仪:原理、比较与对比
J Comput Assist Tomogr. 2013 Nov-Dec;37(6):944-7. doi: 10.1097/RCT.0000000000000028.
7
Determination of the modulation transfer function of digitally reconstructed radiographs in radiotherapy treatment planning using a point phantom.使用点模体在放射治疗计划中确定数字重建射线照片的调制传递函数。
Phys Med Biol. 2005 Oct 21;50(20):N251-5. doi: 10.1088/0031-9155/50/20/N01. Epub 2005 Sep 27.
8
The effect of different adaptation strengths on image quality and radiation dose using Siemens Care Dose 4D.使用西门子Care Dose 4D时不同适应强度对图像质量和辐射剂量的影响。
Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):173-9. doi: 10.1093/rpd/ncq098. Epub 2010 Mar 15.
9
X-ray scatter data for flat-panel detector CT.平板探测器CT的X射线散射数据。
Phys Med. 2007 Mar;23(1):3-15. doi: 10.1016/j.ejmp.2006.12.004. Epub 2007 Mar 28.
10
Statistical reconstruction for x-ray computed tomography using energy-integrating detectors.使用能量积分探测器的X射线计算机断层扫描的统计重建
Phys Med Biol. 2007 Apr 21;52(8):2247-66. doi: 10.1088/0031-9155/52/8/014. Epub 2007 Apr 2.