Zhang Qiu-Shi, Li Jian-Bin, Xu Min, Fan Ting-Yong, Lu Jie, Zhang Ying-Jie, Xing Jun, Tian Shi-Yu
Department of Radiation Oncology, Shandong Cancer Hospital & Institute, Jinan 250117, China.
Zhonghua Zhong Liu Za Zhi. 2010 Dec;32(12):927-31.
To explore the overlap ratio of the target volume in different respiratory statuses of active breath control (ABC) and their differences during external-beam partial breast irradiation (EB-PBI), and from the perspective of target volume overlap to determine the influence of the ABC-assisted breathing condition on intra-fractional target movement of EB-PBI.
The patients, who received breast-conserving surgery with silver clips marked at the margins of the cavity and were suitable for EB-PBI, were immobilized on the breast bracket to undertake CT simulation assisted by ABC device, six sets of CT simulation images including two sets of image in state of moderate deep inspiration breathing control (mDIBH), two sets of images in state of free breath (FB) and two sets of images in state of deep expiration breathing control (DEBH) were obtained. The six sets of images were transferred to Pinnacle(3) treatment planning system (TPS), then automatic fusion and registration between two sets of mDIBH images, two sets of FB images, two sets of DEBH images and mDIBH image and DEBH image were achieved separately. Thereafter, the overlap ratios of GTV with GTV, CTV with CTV, PTV with PTV were calculated by the Pinnacle(3) TPS. The differences between the overlap ratios of the three kinds of targets in the same registered image and the difference between the overlap ratios of the same kind of target in the different registered images were statistically analyzed using statistical package of SPSS 11.5.
Based on mDIBH/mDIBH registration, the overlap ratios of GTV/GTV, CTV/CTV and PTV/PTV were (83.54 ± 11.41)%, (93.00 ± 6.49)%, and (95.26 ± 4.90)%, respectively, and the differences of the overlap ratios between GTV/GTV and CTV/CTV, GTV/GTV and PTV/PTV were all statistically significant (P < 0.05), but statistically not significant between CTV/CTV and PTV/PTV (P > 0.05). Based on FB/FB registration, the overlap ratios of GTV/GTV, CTV/CTV and PTV/PTV were (72.55 ± 29.10)%, (89.36 ± 9.53)% and (92.47 ± 7.25)%, respectively, and the differences of the overlap ratios between GTV/GTV and CTV/CTV, CTV/CTV and PTV/PTV were all not statistically significant (P > 0.05), but statistically significant between GTV/GTV and PTV/PTV (P < 0.05). Based on DEBH/DEBH registration, the overlap ratios of GTV/GTV, CTV/CTV and PTV/PTV were (79.48 ± 22.31)%, (92.83 ± 6.77)% and (95.05 ± 4.81)%, respectively, and the differences of the overlap ratios between GTV/GTV and CTV/CTV (P = 0.000), CTV/CTV and PTV/PTV (P = 0.037), GTV/GTV and PTV/PTV (P = 0.000) were statistically all significant (P = 0.000). The differences of the overlap ratios of GTV/GTV, CTV/CTV, and PTV/PTV (P = 0.000) between mDIBH/mDIBH and DEBH/DEBH, mDIBH/mDIBH and FB/FB, FB/FB and DEBH/DEBH were all statistically significant (P = 0.000), and not statistically significant between mDIBH/mDIBH and mDIBH/DEBH, FB/FB and mDIBH/DEBH.
During the delivering of EB-PBI assisted by ABC, the intra-fractional overlap ratios of the target volume between the same breathing state is increasing in the order of GTV/GTV → CTV/CTV → PTV/PTV. The difference of the overlap ratios of the target volumes between mDIBH and mDIBH, FB and FB, DEBH and DEBH is not significant, and the overlap ratios of PTV/PTV in the three breathing statuses of mDIBH, FB and DEBH reaches a higher level. Therefore, from the perspective of target volume overlap, if the setup error is corrected online before delivering, the necessity of breathing control during delivering of EB-PBI is worthy discussing.
探讨主动呼吸控制(ABC)不同呼吸状态下靶区体积的重叠率及其在外照射部分乳腺放疗(EB - PBI)过程中的差异,并从靶区体积重叠的角度确定ABC辅助呼吸状态对EB - PBI分次内靶区运动的影响。
对接受保乳手术且在腔隙边缘标记银夹、适合EB - PBI的患者,固定于乳腺托架上,在ABC装置辅助下进行CT模拟,获取六组CT模拟图像,包括两组中度深吸气屏气(mDIBH)状态下的图像、两组自由呼吸(FB)状态下的图像和两组深呼气屏气(DEBH)状态下的图像。将这六组图像传输至Pinnacle(3)治疗计划系统(TPS),然后分别实现两组mDIBH图像、两组FB图像、两组DEBH图像之间以及mDIBH图像与DEBH图像之间的自动融合与配准。此后,通过Pinnacle(3)TPS计算GTV与GTV、CTV与CTV、PTV与PTV的重叠率。使用SPSS 11.5统计软件包对同一配准图像中三种靶区重叠率之间的差异以及不同配准图像中同一种靶区重叠率之间的差异进行统计学分析。
基于mDIBH/mDIBH配准,GTV/GTV、CTV/CTV和PTV/PTV的重叠率分别为(83.54 ± 11.41)%、(93.00 ± 6.49)%和(95.26 ± 4.90)%,GTV/GTV与CTV/CTV、GTV/GTV与PTV/PTV重叠率之间的差异均具有统计学意义(P < 0.05),但CTV/CTV与PTV/PTV之间差异无统计学意义(P > 0.05)。基于FB/FB配准,GTV/GTV、CTV/CTV和PTV/PTV的重叠率分别为(72.55 ± 29.10)%、(89.36 ± 9.53)%和(92.47 ± 7.25)%,GTV/GTV与CTV/CTV、CTV/CTV与PTV/PTV重叠率之间的差异均无统计学意义(P > 0.05),但GTV/GTV与PTV/PTV之间差异具有统计学意义(P < 0.05)。基于DEBH/DEBH配准,GTV/GTV、CTV/CTV和PTV/PTV的重叠率分别为(79.48 ± 22.31)%、(92.83 ± 6.77)%和(95.05 ± 4.81)%,GTV/GTV与CTV/CTV(P = 0.000)、CTV/CTV与PTV/PTV(P = 0.037)、GTV/GTV与PTV/PTV(P = 0.000)重叠率之间的差异均具有统计学意义(P = 0.000)。mDIBH/mDIBH与DEBH/DEBH、mDIBH/mDIBH与FB/FB、FB/FB与DEBH/DEBH之间GTV/GTV、CTV/CTV和PTV/PTV重叠率的差异均具有统计学意义(P = 0.000),而mDIBH/mDIBH与mDIBH/DEBH、FB/FB与mDIBH/DEBH之间差异无统计学意义。
在ABC辅助的EB - PBI实施过程中,同一呼吸状态下靶区体积的分次内重叠率按GTV/GTV→CTV/CTV→PTV/PTV的顺序递增。mDIBH与mDIBH、FB与FB、DEBH与DEBH之间靶区体积重叠率的差异无统计学意义,且mDIBH、FB和DEBH三种呼吸状态下PTV/PTV的重叠率达到较高水平。因此,从靶区体积重叠的角度来看,如果在放疗前在线校正摆位误差,EB - PBI放疗过程中呼吸控制的必要性值得探讨。