Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University, 1 Hoeki-dong, Dongdaemun-gu, Seoul, 130-702, Korea.
Knee Surg Sports Traumatol Arthrosc. 2011 May;19(5):816-22. doi: 10.1007/s00167-010-1388-6. Epub 2011 Feb 3.
This study is to compare the clinical and radiographic results of anterior cruciate ligament (ACL) reconstruction with four-stranded autogenous hamstring tendon and two-stranded free tendon Achilles allograft fixed with EndoButton in the femoral tunnel and Intrafix in the tibial tunnel.
106 patients diagnosed with ACL rupture underwent ACL reconstruction. Autogenous hamstring tendon was used in 33 patients (group I) and free tendon Achilles allografts were used in 32 patients (group II). Median age was 23 years old (20-51) in group I and 22 years old (20-55) in group II. Range of motion, Lachman test, Pivot shift test, IKDC score, Lysholm score and side-to-side difference (SSD) were evaluated preoperatively and at the last follow-up. Tegner activity scale was evaluated before injury and at the last follow-up.
The mean follow-up periods were 28.1 months in group I and 31.6 months in group II. Range of motion of the knee was not different from that of the unaffected side in most cases except one flexion deficit in group I and three in group II (n.s.). One in group I and three in group II showed grade two or three laxity on Lachman test at the last follow-up. One in group I and three in group II showed clear positive results on Pivot shift test at the last follow-up. Thirty in group I and 26 in group II were classified to IKDC A or B at the last follow-up (n.s.). Median Lysholm scores were 98 (85-100) in group I and 99 (85-100) in group II at the last follow-up (n.s.). Median Tegner activity scales were 6 (5-9) in group I and 6 (4-9) in group II at the last follow-up (n.s.). The mean SSD at the last follow-up were 1.4 ± 2.0 mm in group I and 1.9 ± 2.4 mm in group II (n.s.).
Clinical and radiological outcomes of ACL reconstruction with two-stranded free tendon Achilles allograft were comparable to those of four-stranded autogenous hamstring tendon. This technique is reasonable to accomplish good results without some weaknesses when using allograft with bone block.
Therapeutic randomized controlled prospective study, Level I.
本研究旨在比较前交叉韧带(ACL)重建中四股自体腘绳肌腱和双股游离跟腱同种异体移植物分别采用 EndoButton 固定于股骨隧道和 Intrafix 固定于胫骨隧道的临床和影像学结果。
106 例 ACL 断裂患者接受 ACL 重建。33 例患者采用自体腘绳肌腱(I 组),32 例患者采用游离跟腱同种异体移植物(II 组)。I 组患者平均年龄 23 岁(20-51 岁),II 组患者平均年龄 22 岁(20-55 岁)。术前和末次随访时评估膝关节活动度、lachman 试验、前抽屉试验、IKDC 评分、Lysholm 评分和侧方差异(SSD)。术前和末次随访时评估 Tegner 活动量表。
I 组平均随访时间为 28.1 个月,II 组为 31.6 个月。除 1 例 I 组患者存在屈曲不足和 3 例 II 组患者存在屈曲不足外,大多数患者膝关节活动度与健侧无差异(无统计学差异)。末次随访时,I 组 1 例和 II 组 3 例 Lachman 试验呈 2 级或 3 级松弛(无统计学差异)。末次随访时,I 组 1 例和 II 组 3 例前抽屉试验呈阳性(无统计学差异)。末次随访时,I 组 30 例和 II 组 26 例 IKDC A 或 B 级(无统计学差异)。I 组末次随访时 Lysholm 评分中位数为 98(85-100),II 组为 99(85-100)(无统计学差异)。末次随访时,I 组 Tegner 活动量表中位数为 6(5-9),II 组为 6(4-9)(无统计学差异)。I 组末次随访时 SSD 平均为 1.4±2.0mm,II 组为 1.9±2.4mm(无统计学差异)。
采用双股游离跟腱同种异体移植物进行 ACL 重建的临床和影像学结果与四股自体腘绳肌腱相似。当使用带骨块的同种异体移植物时,这种技术可以合理地获得良好的效果,而没有一些弱点。
治疗性随机对照前瞻性研究,I 级。