Department of Radiology, Kawasaki Medical School, 577 Matsushima, Kurashiki city, Okayama, 701-0192, Japan.
Eur J Radiol. 2011 Dec;80(3):e284-8. doi: 10.1016/j.ejrad.2010.12.082. Epub 2011 Feb 5.
To compare three different injection methods for optimizing hepatic arterial phase of gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) enhanced MR imaging.
Arterial phase images were obtained after the injection of contrast agent at a rate of 3 mL/s with diluted Gd-EOB-DTPA (dilution method) in 27 patients, 3 mL/s with undiluted Gd-EOB-DTPA (3 mL method) in 26 patients and 1 mL/s with undiluted Gd-EOB-DTPA (1 mL method) in 28 patients. In the quantitative evaluation, signal-to-phantom ratios (SPR) of the liver parenchyma, pancreas, renal cortex, portal vein and aorta were evaluated. In the qualitative evaluation, the seven items for image quality of hepatic arterial phase were assessed, and the total score of all items in each subject was calculated.
The score of enhancement of abdominal aorta and total score of seven items in 1 mL method were significantly higher than those in 3 mL method. The SPR of the liver parenchyma in 3 mL method was significantly higher than that in 1 mL method, suggesting substantial hepatic inflow from portal venous return.
For the optimal arterial phase imaging, injection rate of 1 mL/s with undiluted Gd-EOB-DTPA is convenient and preferable, compared with other two methods, based on our qualitative analysis.
比较三种不同的注射方法,以优化钆塞酸二钠(Gd-EOB-DTPA)增强磁共振成像的肝动脉期。
27 例患者以 3 mL/s 的速率稀释 Gd-EOB-DTPA(稀释法)注射造影剂,26 例患者以 3 mL/s 的速率未稀释 Gd-EOB-DTPA(3 mL 法)注射造影剂,28 例患者以 1 mL/s 的速率未稀释 Gd-EOB-DTPA(1 mL 法)注射造影剂。在定量评估中,评估了肝实质、胰腺、肾皮质、门静脉和主动脉的信号与噪声比(SPR)。在定性评估中,评估了肝动脉期图像质量的七个项目,并计算了每个受试者所有项目的总评分。
1 mL 法的腹主动脉强化评分和七个项目的总评分明显高于 3 mL 法。3 mL 法肝实质的 SPR 明显高于 1 mL 法,提示有大量门静脉回流的肝内流入。
基于我们的定性分析,与其他两种方法相比,以 1 mL/s 的速率注射未稀释的 Gd-EOB-DTPA 是一种方便且优选的动脉期成像方法。