An undulator-based beamline was built and commissioned at the National Synchrotron Light Source to provide tunable coherent radiation in the 200-800 eV range. The low emittance of the storage ring means that the undulator source has high brightness so that a large flux of coherent x rays is delivered to experimental stations. The beamline uses a horizontally dispersing bichromator that allows two experiments to run simultaneously, making use of the first and second harmonics of the undulator output. In addition, the use of horizontally deflecting optics enables the beamline alignment to be insensitive to electron beam motion since the horizontal electron beam size is quite large. The beamline and its performance are discussed with emphasis on the optics and on stability, radiation, and vacuum considerations.

摘要

基于波动器的光束线在国家同步辐射光源上搭建并调试完成,以提供在 200-800 eV 范围内可调谐的相干辐射。储存环的低发射度意味着波动器源具有高亮度,从而将大量相干 X 射线传输到实验站。该光束线使用水平色散双色仪,允许同时运行两个实验,利用波动器输出的第一和第二谐波。此外,使用水平偏转光学器件使光束线对准对电子束运动不敏感,因为水平电子束尺寸相当大。本文讨论了光束线及其性能,重点介绍了光学器件以及稳定性、辐射和真空方面的考虑。

相似文献

1
Coherent Radiation for X-Ray Imaging-The Soft X-Ray Undulator and the X1A Beamline at the NSLS.
J Xray Sci Technol. 1990 Jan 1;2(4):274-96. doi: 10.3233/XST-1990-2404.
2
Illumination for coherent soft X-ray applications: the new X1A beamline at the NSLS.
J Synchrotron Radiat. 2000 Nov 1;7(Pt 6):395-404. doi: 10.1107/S0909049500012942.
3
Beamline X29: a novel undulator source for X-ray crystallography.
J Synchrotron Radiat. 2006 Sep;13(Pt 5):365-72. doi: 10.1107/S0909049506027853. Epub 2006 Aug 12.
4
Small-gap insertion-device development at the National Synchrotron Light Source--performance of the new X13 mini-gap undulator.
J Synchrotron Radiat. 2004 Mar 1;11(Pt 2):129-31. doi: 10.1107/S0909049503022921. Epub 2004 Feb 12.
5
Optics Concept for a Pair of Undulator Beamlines for MX.
Nucl Instrum Methods Phys Res A. 2011 Sep 1;649(1):131-135. doi: 10.1016/j.nima.2010.12.030.
7
Beam-position monitors in the X-ray undulator beamline at PETRA.
J Synchrotron Radiat. 1998 May 1;5(Pt 3):627-9. doi: 10.1107/S0909049597013940.
8
Undulator beamline of the Brockhouse sector at the Canadian Light Source.
Rev Sci Instrum. 2014 Aug;85(8):085104. doi: 10.1063/1.4890815.
9
Performance calculations of the X-ray powder diffraction beamline at NSLS-II.
J Synchrotron Radiat. 2013 Mar;20(Pt 2):234-42. doi: 10.1107/S0909049512049175. Epub 2013 Jan 23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验