膝关节置换术中股骨夹具旋转对线的组内和组间变异性。

Intra- and inter-observer variation during femoral jig rotational alignment in knee arthroplasty.

机构信息

Department of Trauma and Orthopaedics, Queens Medical Centre, Nottingham, Nottinghamshire, UK.

出版信息

Arch Orthop Trauma Surg. 2011 Sep;131(9):1283-6. doi: 10.1007/s00402-011-1273-x. Epub 2011 Feb 18.

Abstract

INTRODUCTION/AIMS: Rotational alignment of the femoral prosthesis is important in total knee arthroplasty to improve performance and reduce complications. This study investigates the differences between two popular referencing methods and evaluates the variability of surgeons' techniques (inter-observer) and their reproducibility (intra-observer) of femoral alignment.

METHODS

Eight surgeons each established the femoral rotational alignment on four duplicate sets of six cadaveric femoral bone casts, referencing from the epicondylar axis and from the posterior femoral condyles. These derived axes were compared against a reference Whiteside's line (anteroposterior axis).

RESULTS/SUMMARY: There was no significant difference between referencing techniques and a tendency to align the femoral component in slight external rotation. Femoral rotational alignment was reproducible by each surgeon. Extensive and significant variation in alignment exists between surgeons, independent of other factors (p < 0.001).

摘要

引言/目的:在全膝关节置换术中,股骨假体的旋转对线对于提高性能和减少并发症非常重要。本研究调查了两种流行的参考方法之间的差异,并评估了外科医生技术(观察者间)的可变性及其股骨对线的可重复性(观察者内)。

方法

八位外科医生每人在四组六个尸体股骨骨模型上建立了股骨旋转对线,参考了髁上轴和股骨后髁。这些导出的轴线与参考的 Whiteside 线(前后轴线)进行了比较。

结果/总结:参考技术之间没有显著差异,股骨组件有轻微外旋的倾向。每位外科医生都可以重复股骨的旋转对线。外科医生之间的对线存在广泛且显著的差异,与其他因素无关(p < 0.001)。