Abstract

Hematic cyst formation after placement of nonporous alloplastic orbital floor implants is well described. A benefit of porous polyethylene is fibrovascular ingrowth without capsular formation. This ingrowth inhibits hematic cyst formation. In the case presented here, a hematic cyst developed on a screw-fixated porous polyethylene/titanium mesh implant (Medpor Titan B-T-M, Porex Surgical, Newnan, GA, U.S.A.). The risk factor for this patient was the nonporous barrier surface of the implant and inadequate fracture reduction. Proper surgical technique, including implant sizing, placement, and fixation, are factors reported to prevent hematic cyst formation. This patient's symptoms resolved after removal of the implant and cyst and replacement of the orbital implant.

摘要

放置非多孔异体眼眶底植入物后出现含血囊肿已有明确的描述。多孔聚乙烯的一个优点是纤维血管长入而无囊形成。这种长入可抑制含血囊肿的形成。在此例中,在一个螺钉固定的多孔聚乙烯/钛网植入物(Medpor Titan B-T-M,Porex Surgical,Newnan,GA,美国)上形成了含血囊肿。该患者的危险因素是植入物的非多孔屏障表面和骨折复位不足。据报道,适当的手术技术,包括植入物的大小、放置和固定,是预防含血囊肿形成的因素。该患者在取出植入物和囊肿并更换眼眶植入物后症状得到缓解。