Suppr超能文献

经皮肝穿门静脉-肠系膜上静脉分流术治疗肝外门静脉阻塞的双功超声评估经验。

Experience with duplex sonographic evaluation of meso-rex bypass in extrahepatic portal vein obstruction.

作者信息

Chen Wei, Rodriguez-Davalos Manuel I, Facciuto Marcelo E, Rachlin Susan

机构信息

Department of Radiology, Westchester Medical Center, Valhalla, New York, USA.

出版信息

J Ultrasound Med. 2011 Mar;30(3):403-9. doi: 10.7863/jum.2011.30.3.403.

Abstract

Meso-Rex bypass is a surgical procedure for managing extrahepatic portal vein obstruction in children. Although duplex sonography has been used for assessing the patency of the bypass graft and the changes in the intrahepatic portal venous system after the surgery, there was little sonographic description of functioning and dysfunctioning bypass grafts found in the literature. In this case series, we retrospectively evaluated duplex sonography of functioning and dysfunctioning bypass grafts in 5 pediatric patients who received meso-Rex bypass grafts. Sonography was performed preoperatively and postoperatively within 48 hours, 1 to 2 weeks later, and at follow-up 1 month and up to 3 years later. Changes in the direction and velocity of the flow in the intrahepatic portal veins and bypass grafts and diameters of the grafts and the left portal veins were analyzed. Preoperative sonography revealed varied extension of extrahepatic portal vein occlusion with cavernous transformation and diminished intrahepatic portal venous flow, whereas postoperative studies showed a rapid increase of the intrahepatic portal flow via the meso-Rex bypass graft in all cases. A patent graft with reversed flow in the left portal vein was a predominant feature of a functioning graft. In contrast, absent flow in the graft with diminished flow or an altered flow direction in the left portal vein indicated graft failure. It is believed that duplex sonography provides a valuable tool for monitoring the hemodynamic changes in the portal venous system and detecting graft malfunction.

摘要

肠系膜上静脉-肝内门静脉左支分流术(Meso-Rex bypass)是一种用于治疗儿童肝外门静脉阻塞的外科手术。尽管双功超声已被用于评估分流移植血管的通畅情况以及术后肝内门静脉系统的变化,但文献中很少有关于功能正常和功能异常的分流移植血管的超声描述。在这个病例系列中,我们回顾性评估了5例接受肠系膜上静脉-肝内门静脉左支分流术的儿科患者中功能正常和功能异常的分流移植血管的双功超声情况。术前以及术后48小时内、1至2周后、1个月随访时以及长达3年后均进行了超声检查。分析了肝内门静脉和分流移植血管内血流方向和速度的变化以及移植血管和门静脉左支的直径。术前超声显示肝外门静脉阻塞伴海绵样变性的范围各异,肝内门静脉血流减少,而术后研究显示所有病例中通过肠系膜上静脉-肝内门静脉左支分流移植血管的肝内门静脉血流迅速增加。门静脉左支血流反向的通畅移植血管是功能正常的移植血管的主要特征。相比之下,移植血管内无血流、血流减少或门静脉左支血流方向改变则提示移植血管功能衰竭。据信,双功超声为监测门静脉系统的血流动力学变化和检测移植血管功能障碍提供了一种有价值的工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验