Suppr超能文献

长期单侧无晶状体眼的二期人工晶状体植入术。

Secondary intraocular lens implantation in longstanding unilateral aphakia.

作者信息

Choi Hyuk Jin, Lee Jin Hak, Hwang Jeong-Min

机构信息

Department of Ophthalmology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea.

出版信息

Optom Vis Sci. 2011 May;88(5):608-12. doi: 10.1097/OPX.0b013e31820cdc94.

Abstract

PURPOSE

To investigate the effect of secondary intraocular lens (IOL) implantation on binocular vision in patients with unilateral aphakia uncorrected consecutively for 3 years or more.

METHODS

This study included nine patients who underwent secondary IOL implantation, but had remained in a unilateral aphakic state, without being corrected, for at least 3 consecutive years at the time of the secondary IOL implant. They also had a postoperative best-corrected visual acuity of better than 20/40 in both eyes. All patients underwent an ophthalmologic examination including best spectacle-corrected visual acuity and binocular alignment. Stereoacuity was evaluated using the Titmus Stereotest and a stereoacuity of 100 sec of arc or better was designated as "good" stereoacuity. Binocularity was determined using the polarized 4-dot test at distance and at near and the reporting of 4 dots were used to establish fusional ability.

RESULTS

Four of the nine patients (44.4%) showed the highest stereoacuity of 40 sec of arc and another four patients (44.4%) showed a stereoacuity of 50 or 60 sec of arc. Only one patient showed "poor" stereoacuity of 200 sec of arc. All the patients could fuse at near and at distance on the polarized 4-dot test. Diplopia and anomalous eye movements were not found in any patient.

CONCLUSIONS

Secondary IOL implantation can provide good binocular vision even in patients with unilateral aphakia who had not been corrected for 3 years or more.

摘要

目的

探讨二期人工晶状体(IOL)植入对单侧无晶状体且连续3年以上未矫正患者双眼视觉的影响。

方法

本研究纳入9例接受二期IOL植入的患者,这些患者在二期IOL植入时至少连续3年处于单侧无晶状体且未矫正状态。他们术后双眼最佳矫正视力均优于20/40。所有患者均接受眼科检查,包括最佳眼镜矫正视力和双眼眼位。使用Titmus立体视检查评估立体视锐度,立体视锐度100角秒或更好被定义为“良好”立体视锐度。使用偏振四点试验在远距离和近距离测定双眼视功能,通过四点的报告来确定融合能力。

结果

9例患者中有4例(44.4%)立体视锐度最高为40角秒,另外4例患者(44.4%)立体视锐度为50或60角秒。只有1例患者立体视锐度为200角秒,属于“差”的立体视锐度。所有患者在偏振四点试验的远距离和近距离均能融合。所有患者均未出现复视和异常眼球运动。

结论

即使是单侧无晶状体且3年以上未矫正的患者,二期IOL植入也能提供良好的双眼视觉。