The aim of this study was to determine the results of operative treatment of distal radial fractures with a 2.4-mm locking plate system in a single tertiary teaching hospital. Seventy-five patients were recruited into the study between May 2004 and November 2006. There were 41 males and 34 females, with a mean age of 51. Seventy-five percent of patients had AO type C fractures. All patients were allowed free active mobilisation of the wrist joint immediately after surgery. They were followed up at two weeks, three months, six months, one year and two years. Assessments of pain, motion, grip strength, and standard radiographs were performed. The Gartland and Werley functional scores, the modified Green and O'Brien score, and the disabilities of the arm, shoulder and hand (DASH) scores were recorded. The radiographic results at the final follow-up showed a mean of 18° of radial inclination, 5° of volar tilt, 1.3-mm radial shortening, and no articular incongruity. Twenty-nine percent of patients showed grade 1 osteoarthritic changes and 6% had grade 2 changes in their final follow-up radiographs. An excellent or good result was obtained in 98% and 96% of patients according to the Gartland and Werley, and modified Green and O'Brien scores, respectively. The mean DASH score was 11.6, indicating a high level of patient satisfaction. Internal fixation of distal radial fractures with a 2.4-mm locking plate system provided a stable fixation with good clinical outcomes and patient satisfaction.

摘要

本研究旨在探讨在一家三级教学医院中,使用 2.4mm 锁定钢板系统治疗桡骨远端骨折的手术效果。2004 年 5 月至 2006 年 11 月期间,共招募了 75 例患者。其中男性 41 例,女性 34 例,平均年龄为 51 岁。75%的患者为 AO 分型 C 型骨折。所有患者术后均允许立即自由活动腕关节。在术后 2 周、3 个月、6 个月、1 年和 2 年进行随访。评估疼痛、活动度、握力以及标准 X 线片。记录 Gartland 和 Werley 功能评分、改良 Green 和 O'Brien 评分以及残疾程度(DASH)评分。末次随访时 X 线片显示,平均桡骨倾斜角为 18°,掌倾角为 5°,桡骨缩短 1.3mm,无关节不平整。29%的患者在末次随访时出现 1 级骨关节炎改变,6%的患者出现 2 级改变。根据 Gartland 和 Werley 评分,98%和 96%的患者获得了优秀或良好的结果;根据改良 Green 和 O'Brien 评分,分别有 98%和 96%的患者获得了优秀或良好的结果。DASH 平均评分为 11.6,表明患者满意度高。使用 2.4mm 锁定钢板系统内固定桡骨远端骨折可获得稳定固定,临床效果和患者满意度良好。

相似文献

引用本文的文献

本文引用的文献

6
Management of distal radial fractures.桡骨远端骨折的治疗
J Bone Joint Surg Am. 2007 Sep;89(9):2051-62. doi: 10.2106/JBJS.G.00020.
9
X-ray film measurements for healed distal radius fractures.愈合的桡骨远端骨折的X线片测量
J Hand Surg Am. 1996 Jan;21(1):31-9. doi: 10.1016/S0363-5023(96)80151-1.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验