Suppr超能文献

使用 Frank 序列进行脉冲 EPR。

Use of the Frank sequence in pulsed EPR.

机构信息

Department of Chemistry and Biochemistry, University of Denver, Denver, CO 80208, USA.

出版信息

J Magn Reson. 2011 Apr;209(2):306-9. doi: 10.1016/j.jmr.2011.01.032. Epub 2011 Feb 3.

Abstract

The Frank polyphase sequence has been applied to pulsed EPR of triarylmethyl radicals at 25 6 MHz (9.1 mT magnetic field), using 256 phase pulses. In EPR, as in NMR, use of a Frank sequence of phase steps permits pulsed FID signal acquisition with very low power microwave/RF pulses (ca. 1.5 mW in the application reported here) relative to standard pulsed EPR. A 0.2 mM aqueous solution of a triarylmethyl radical was studied using a 16 mm diameter cross-loop resonator to isolate the EPR signal detection system from the incident pulses.

摘要

已将弗兰克多相序列应用于在 256 MHz(9.1 mT 磁场)下的三芳基甲基自由基的脉冲 EPR,使用 256 个相脉冲。在 EPR 中,与标准脉冲 EPR 相比,与使用非常低功率微波/RF 脉冲(在此应用中约为 1.5 mW)相对应,使用弗兰克相步序列可以实现脉冲 FID 信号的采集。研究了浓度为 0.2 mM 的三芳基甲基自由基的水溶液,使用 16mm 直径的十字环谐振器将 EPR 信号检测系统与入射脉冲隔离开来。

相似文献

1
Use of the Frank sequence in pulsed EPR.
J Magn Reson. 2011 Apr;209(2):306-9. doi: 10.1016/j.jmr.2011.01.032. Epub 2011 Feb 3.
2
Use of polyphase continuous excitation based on the Frank sequence in EPR.
J Magn Reson. 2011 Aug;211(2):221-7. doi: 10.1016/j.jmr.2011.06.005. Epub 2011 Jun 12.
3
A Dynamic Nuclear Polarization spectrometer at 95 GHz/144 MHz with EPR and NMR excitation and detection capabilities.
J Magn Reson. 2011 Apr;209(2):136-41. doi: 10.1016/j.jmr.2010.12.010. Epub 2011 Jan 1.
4
Nonselective excitation of pulsed ELDOR using multi-frequency microwaves.
J Magn Reson. 2011 Dec;213(1):200-5. doi: 10.1016/j.jmr.2011.09.034. Epub 2011 Sep 17.
6
A bridged loop-gap S-band surface resonator for topical EPR spectroscopy.
J Magn Reson. 2001 Jul;151(1):124-8. doi: 10.1006/jmre.2001.2349.
7
A 140 GHz pulsed EPR/212 MHz NMR spectrometer for DNP studies.
J Magn Reson. 2012 Oct;223:170-9. doi: 10.1016/j.jmr.2012.07.008. Epub 2012 Jul 20.
8
A continuous-wave and pulsed electron spin resonance spectrometer operating at 275 GHz.
J Magn Reson. 2004 Jan;166(1):92-9. doi: 10.1016/j.jmr.2003.10.011.
9
Towards reduction of SAR in scaling up in vivo pulsed EPR imaging to larger objects.
J Magn Reson. 2019 Feb;299:42-48. doi: 10.1016/j.jmr.2018.12.011. Epub 2018 Dec 14.

引用本文的文献

1
Towards reduction of SAR in scaling up in vivo pulsed EPR imaging to larger objects.
J Magn Reson. 2019 Feb;299:42-48. doi: 10.1016/j.jmr.2018.12.011. Epub 2018 Dec 14.
2
The world as viewed by and with unpaired electrons.
J Magn Reson. 2012 Oct;223:151-63. doi: 10.1016/j.jmr.2012.07.025. Epub 2012 Aug 15.
3
Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency.
J Magn Reson. 2011 Dec;213(1):119-25. doi: 10.1016/j.jmr.2011.09.024. Epub 2011 Sep 14.
4
Use of polyphase continuous excitation based on the Frank sequence in EPR.
J Magn Reson. 2011 Aug;211(2):221-7. doi: 10.1016/j.jmr.2011.06.005. Epub 2011 Jun 12.
5
Rapid frequency scan EPR.
J Magn Reson. 2011 Aug;211(2):156-61. doi: 10.1016/j.jmr.2011.05.006. Epub 2011 May 19.

本文引用的文献

1
A Wire Crossed-Loop-Resonator for Rapid Scan EPR.
Concepts Magn Reson Part B Magn Reson Eng. 2010 Apr 9;37B(2):86-91. doi: 10.1002/cmr.b.20161.
2
NMR with excitation modulated by Frank sequences.
J Magn Reson. 2009 Jul;199(1):18-24. doi: 10.1016/j.jmr.2009.03.009. Epub 2009 Mar 28.
3
Background removal procedure for rapid scan EPR.
J Magn Reson. 2009 Jan;196(1):48-53. doi: 10.1016/j.jmr.2008.10.012. Epub 2008 Oct 15.
4
Rapid-scan EPR with triangular scans and fourier deconvolution to recover the slow-scan spectrum.
J Magn Reson. 2005 Jul;175(1):44-51. doi: 10.1016/j.jmr.2005.03.013. Epub 2005 Apr 14.
6
Direct-detected rapid-scan EPR at 250 MHz.
J Magn Reson. 2004 Sep;170(1):127-35. doi: 10.1016/j.jmr.2004.06.008.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验