Suppr超能文献

定量肌肉硬度作为一种非侵入性手段,用于检测有发生筋膜间室综合征风险的患者。

Quantitative muscle hardness as a noninvasive means for detecting patients at risk of compartment syndromes.

机构信息

Jacksonville Orthopaedic Institute, 1325 San Marco Blvd, Ste. 200, Jacksonville, FL 32207, USA.

出版信息

Physiol Meas. 2011 Apr;32(4):433-44. doi: 10.1088/0967-3334/32/4/005. Epub 2011 Mar 8.

Abstract

The purpose of this project was to study the efficacy of quantitative muscle hardness (QH) curve analysis for noninvasive measurement of muscle compartment interstitial pressure (IMP), and to eliminate the need for a comparison normal QH measurement to determine a pathologic reading. Elevation of IMP may lead to limb compartment syndrome, which may result in irreversible dysfunction, chronic pain and contracture. Two studies were performed by two separate independent examiners on male volunteers, where IMP measurements and QH curves were obtained. QH curves were divided into three parts comparing the third part to the second part using the coefficient of determination (R(2)). In 205 limb compartments, there were 1432 comparison readings of the IMP versus R(2). Using receiver operator characteristic curve analysis for all data from both studies, an R(2) cutoff of 0.974 best corresponded to a pathologic IMP of 50 mmHg. For both sets of data and for each compartment tested, the mean IMP values were statistically different (t-test: P < 0.0001) for the group with R(2) values less than 0.974 compared to the group of R(2) values greater than or equal to 0.974. In addition, a pressure prediction model was formulated with a strong overall correlation coefficient of 0.78. The data of this study support that QH analysis is potentially useful for the monitoring of IMP elevation in compartment syndrome.

摘要

本项目旨在研究定量肌肉硬度(QH)曲线分析在无创测量肌肉间隔腔压力(IMP)方面的功效,并消除对比较正常 QH 测量以确定病理读数的需求。IMP 的升高可能导致肢体间隔综合征,从而导致不可逆的功能障碍、慢性疼痛和挛缩。本研究由两位独立的检查者在男性志愿者身上进行了两项研究,其中获得了 IMP 测量和 QH 曲线。QH 曲线分为三部分,使用决定系数(R(2))比较第三部分与第二部分。在 205 个肢体间隔中,有 1432 次 IMP 与 R(2)的比较读数。使用来自两项研究的所有数据的接收者操作特征曲线分析,R(2)截距为 0.974 时最符合病理 IMP 为 50mmHg 的情况。对于两组数据和每个测试的隔间,R(2)值小于 0.974 的组与 R(2)值大于或等于 0.974 的组之间的平均 IMP 值存在统计学差异(t 检验:P<0.0001)。此外,还制定了一个压力预测模型,具有很强的总体相关系数为 0.78。本研究的数据支持 QH 分析在监测间隔综合征中 IMP 升高方面具有潜在的用途。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验