Suppr超能文献

低新鲜气流率对七氟醚消耗量的影响。

The effect of low fresh gas flow rate on sevoflurane consumption.

机构信息

Department of Anesthesiology and Pain Medicine, Boramae Medical Center, Seoul, Korea.

出版信息

Korean J Anesthesiol. 2011 Feb;60(2):75-7. doi: 10.4097/kjae.2011.60.2.75. Epub 2011 Feb 25.

Abstract

BACKGROUND

In an era of medical cost containment, cost-effectiveness has become a major focus in healthcare. The effect of a new policy on the use of low fresh gas flow during maintenance of general anesthesia with volatile anesthetics was evaluated.

METHODS

The numbers and duration of general anesthesia cases using sevoflurane 5 weeks prior to and 15 weeks after policy implementation were retrieved from the electronic medical records database. The number of sevoflurane bottles consumed was also assessed. The anesthesia hours per bottle of sevoflurane were compared before and after policy implementation.

RESULTS

The number of anesthesia hours performed per bottle of sevoflurane increased by 38.3%. The effect varied over time and tended to fade with time.

CONCLUSIONS

The implementation of a low fresh gas flow rate policy effectively reduces the amount of sevoflurane consumed for the same duration of anesthesia.

摘要

背景

在医疗成本控制的时代,成本效益已成为医疗保健的主要关注点。评估了一项新政策对使用挥发性麻醉剂维持全身麻醉时低新鲜气流的影响。

方法

从电子病历数据库中检索了政策实施前 5 周和实施后 15 周使用七氟醚的全身麻醉病例数和持续时间。还评估了七氟醚瓶的消耗量。比较了政策实施前后每瓶七氟醚的麻醉小时数。

结果

每瓶七氟醚的麻醉小时数增加了 38.3%。这种效果随时间而变化,并随着时间的推移而趋于减弱。

结论

实施低新鲜气流速率政策可有效减少相同麻醉持续时间内七氟醚的消耗量。