Suppr超能文献

体内研究基质系统对 2 面和 3 面后牙复合树脂修复体近中边缘密合度的影响

Influence of matrix systems on proximal contact tightness of 2- and 3-surface posterior composite restorations in vivo.

机构信息

Department of Conservative Dentistry and Periodontology, Julius-Maximilians-University of Würzburg, Würzburg, Germany.

出版信息

J Dent. 2011 May;39(5):386-90. doi: 10.1016/j.jdent.2011.03.001. Epub 2011 Mar 21.

Abstract

OBJECTIVES

To investigate the influence of cavity preparation (MO/DO/MOD) and type of matrix system on proximal contact tightness of direct posterior composite restorations.

MATERIALS AND METHODS

85 patients in need of a two- or three surface Class II direct composite restoration were randomly divided into two treatment groups. Group 1 was treated with a sectional matrix system combined with a separation ring (Palodent); Group 2 was treated with a circumferential matrix system in combination with a retainer (Tofflemire). Proximal contact tightness was recorded before treatment and directly after finishing the restoration.

RESULTS

For the two-surface cavities use of the separation ring resulted in a statistically significantly tighter proximal contacts at both the mesial and distal site (MO: 2.51±0.81 N; DO: 2.82±1.14 N) compared to the use of the circumferential (MO: -1.08±1.04 N; DO: -0.22±0.87 N) (p=0.01). Regarding the three-surface (MOD) cavities no statistically significant differences were found between the mesial and distal site, nor was there an effect of the used matrix system. No statistically significant influence of cavity design (mesially/distally) was recorded for all cavities (MO, DO and MOD).

CONCLUSIONS

Use of the sectional matrix system in two-surface Class II cavities resulted in statistically significantly tighter proximal contacts than the use of the circumferential matrix system. For the three-surface no statistically significant differences in contact tightness were found between the different matrix systems. Location of the cavity (mesially or distally) did not show to have any statistically significant effect on the obtained proximal contact tightness.

摘要

目的

研究窝洞预备(MO/DO/MOD)和不同垫底材料对直接后牙复合树脂修复体邻面密合度的影响。

材料和方法

85 名患者需要进行两或三个面的 II 类直接复合树脂修复,随机分为两组。实验组 1 使用分段式楔子系统联合分离环(Palodent),实验组 2 使用环形楔子系统联合固位夹(Tofflemire)。治疗前和修复完成后即刻分别记录近中、远中邻面接触情况。

结果

对于两牙面窝洞,使用分离环时近中、远中邻面接触均明显更紧密(MO:2.51±0.81 N;DO:2.82±1.14 N),而使用环形时则明显较松(MO:-1.08±1.04 N;DO:-0.22±0.87 N)(p=0.01)。对于三牙面窝洞,近中、远中邻面接触均无统计学差异,楔子系统的使用也无影响。对于所有窝洞(MO、DO 和 MOD),窝洞位置(近中或远中)均未对邻面接触产生显著影响。

结论

在两牙面 II 类窝洞使用分段式楔子系统可获得更紧密的邻面接触,而环形系统则较松。对于三牙面窝洞,不同楔子系统对邻面接触的影响无统计学差异。窝洞位置(近中或远中)对获得的邻面接触紧密度无显著影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验