Suppr超能文献

使用四种不同牙科成形片系统评估II类修复体的解剖接触和外形:一项比较分析。

Assessment of anatomical contacts and contours of class II restorations using four different dental matrix systems: An comparative analysis.

作者信息

Panda Deva Nanda, Kaushik Mamta, Mehra Neha, Verma Neha, Dwivedi Aishwarya

机构信息

Private Practitioner, Poulomi Dental Clinic, Secunderabad, India.

Department of Conservative Dentistry and Endodontics, Army College of Dental Sciences, Secunderabad, India.

出版信息

J Conserv Dent Endod. 2025 May;28(5):449-455. doi: 10.4103/JCDE.JCDE_143_25. Epub 2025 May 6.

Abstract

CONTEXT

The assessment of reestablishment of correct anatomic contour and proximal tightness with minimal gingival overhang of a class II restoration.

AIM

This study evaluated and compared the gingival overhang, contact, and contour anatomy achieved by four matrix systems for class II restorations.

MATERIALS AND METHOD

Standardized class II mesio-occlusal conservative cavities were prepared on two hundred typodont teeth and assigned into four groups ( = 50): Tofflemire, U Band system, Palodent V3 matrix system, and Walser Matrix system. The cavities were restored with composite and qualitatively analyzed for proximal contact tightness. The morphology of the overhang and contour was assessed using a Medit scanner and Mesh Labs by superimposition.

STATISTICAL ANALYSIS USED

Kruskal-Wallis nonparametric test of significance and Mann-Whiteny -test for pair-wise comparison was used.

RESULTS

The restorations showed statistically significant difference, with Walser matrix system and U Band demonstrating minimal overhang. No significant difference was observed for contact tightness among the groups ( = 0.109). Contours were assessed at the occlusal, middle, and cervical thirds. The Walser matrix system provided the best gingival contour ( = 0.000). The Palodent V3 matrix yielded the best contour at the middle ( = 0.002) and occlusal ( = 0.036) third with minimum deviation from optimal contour.

CONCLUSIONS

The sectional precontoured matrix system Palodent V3 system recreated the best proximal contour and contact anatomy, while minimal overhang was generated by the Walser matrix.

摘要

背景

评估Ⅱ类修复体正确解剖外形的重建以及近端贴合度,同时使牙龈悬突最小化。

目的

本研究评估并比较了用于Ⅱ类修复体的四种成形片系统所实现的牙龈悬突、邻接关系和外形解剖情况。

材料与方法

在200颗模型牙上制备标准化的Ⅱ类近中咬合面保守洞型,并分为四组(每组n = 50):Tofflemire成形片、U型带系统、Palodent V3成形片系统和Walser成形片系统。用复合树脂修复洞型,并对近端邻接紧密性进行定性分析。使用Medit扫描仪和Mesh Labs通过叠加来评估悬突和外形的形态。

所用统计分析方法

采用Kruskal-Wallis非参数显著性检验和Mann-Whiteny检验进行两两比较。

结果

修复体显示出统计学上的显著差异,Walser成形片系统和U型带的悬突最小。各组之间在邻接紧密性方面未观察到显著差异(P = 0.109)。在咬合面、中部和颈部三分之一处评估外形。Walser成形片系统提供了最佳的牙龈外形(P = 0.000)。Palodent V3成形片在中部(P = 0.002)和咬合面三分之一处(P = 0.036)产生的外形与最佳外形的偏差最小。

结论

分段预成外形的Palodent V3成形片系统重建了最佳的近端外形和邻接解剖结构,而Walser成形片产生的悬突最小。