The placement of a headless screw within the scaphoid is important for successful fixation of fractured scaphoids. We ascertained the safe position of a screw using virtual collision experiments on a three-dimensionally reconstructed scaphoid bone and screw model, and applied measured angles to simple radiographs. We used images from computed tomograms of the wrists taken from 13 men to reconstruct a three-dimensional cortical image of the scaphoid. Inside the bone, we inserted a virtually reconstructed Herbert screw model and calculated the safe angle along the long axis of the scaphoid at which the screw did not collide with the bone in any sample, then applied measured safe angles to simple anteroposterior and lateral radiographs. In all experiments, the safe angle between the screw and the anteroposterior scaphoid line (defined from the most distal portion of the scaphoid where it met the capitate to the proximal position where the lunate and capitate meet) ranged from 8° to 27° in the anteroposterior view, and the safe angle between the screw and the lateral scaphoid line (defined from the most volar portion of the scaphoid tuberosity to the volar position where the scaphoid faced the radius) ranged from 2° to 26° in the lateral view. These ranges can be used as a guide for a safe position of the screw within the scaphoid in volar percutaneous fixation of screws in scaphoid fractures.

摘要

在舟状骨内放置无头螺钉对于舟状骨骨折的成功固定至关重要。我们通过在三维重建的舟状骨和螺钉模型上进行虚拟碰撞实验来确定螺钉的安全位置,并将测量角度应用于简单的X线片。我们使用了13名男性手腕的计算机断层扫描图像来重建舟状骨的三维皮质图像。在骨内,我们插入了虚拟重建的Herbert螺钉模型,并计算了沿舟状骨长轴的安全角度,在任何样本中该角度下螺钉都不会与骨发生碰撞,然后将测量的安全角度应用于简单的前后位和侧位X线片。在所有实验中,螺钉与舟状骨前后线(从舟状骨与头状骨相接的最远端至月骨与头状骨相接处近端所定义)之间的安全角度在前后位视图中为8°至27°,螺钉与舟状骨侧线(从舟状骨结节最掌侧部分至舟状骨面对桡骨的掌侧位置所定义)之间的安全角度在侧位视图中为2°至26°。这些范围可作为舟状骨骨折掌侧经皮螺钉固定时螺钉在舟状骨内安全位置的指导。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验