This study deals with the determination of the retentive forces of telescopic crowns measured extra- and intra-orally and the correlation of these values.
The telescopic denture is a well-documented solution for prosthetic rehabilitation for a partially edentulous jaw. Acceptable retention forces are needed to avoid inadvertent removal of the denture during movement of the jaws. Recent literature suggests 3-7 N per attachment to be acceptable. These values are only supported by in vitro studies. In vivo data are scarce, and a correlation of the in vitro and in vivo values is lacking.
Twenty-five combined fixed-removable prostheses with a total of 72 double crowns were used for extra-oral retention force measurement prior to cementation (in vitro). The intra-oral measurement was performed at 72 defined measuring points of the dentures 4-6 weeks after prosthetic rehabilitation (in vivo). A specifically designed measuring device was used.
The rank correlation showed that the in vitro and in vivo values correlate with each other (Spearman's ρ = 0.5052). Additionally, it was found that the median values measured before (1.97N) insertion of the dentures were significantly lower than after (4.70N) insertion (Mann-Whitney test, p ≤ 0.0001).
The retention forces measured before and after insertion of the denture correlate with each other although their dimension is significantly higher after insertion. The reason for this behaviour might be some tilting during removal. Nevertheless, the correlation allows a prediction of the clinically relevant forces by a measurement of the extra-orally measured retentive values.
本研究旨在测定体外和体内测量的伸缩冠保持力,并探讨这些值之间的相关性。
伸缩式义齿是一种经过充分验证的部分缺牙颌修复体解决方案。为了避免义齿在颌骨运动过程中意外脱落,需要有足够的固位力。最近的文献表明,每个附着体需要 3-7N 的固位力是可以接受的。这些值仅得到体外研究的支持。体内数据稀缺,体外和体内值之间缺乏相关性。
使用 25 个联合固定可摘义齿,共 72 个双冠,在粘固前(体外)进行体外保持力测量。在修复后 4-6 周(体内),在义齿的 72 个定义测量点进行口内测量。使用专门设计的测量装置。
等级相关分析显示,体外和体内值相互相关(Spearman ρ=0.5052)。此外,还发现义齿插入前(1.97N)测量的中位数明显低于插入后(4.70N)(Mann-Whitney 检验,p≤0.0001)。
义齿插入前后测量的保持力相互相关,尽管插入后其尺寸明显更高。这种行为的原因可能是在移除过程中存在一些倾斜。然而,这种相关性允许通过测量体外测量的保持值来预测临床相关的力。