The aim of this study was to evaluate the effects of C-factor and resin volume on the regional bond strength of dual-cure luting resin to root canal dentine.
Twelve single-root human premolars were decoronated and post space prepared to a depth of 8 mm, with a diameter of 1.5 mm for six roots and 1.75 mm for the other six. Root canal dentine was treated with a dual-cure bonding system and light-cured for 20 s. Specimens were filled with a dual-cure resin composite with or without insertion of 1.4-mm-diameter light-transmitting glass fibre posts, followed by light-curing for 60s from the coronal direction. After 24 h water storage, each specimen was serially sliced into eight 0.6 mm × 0.6 mm thick beams for a microtensile bond strength test. Failure modes were observed using SEM. Bond strength data were divided into coronal and apical regions and statistically analysed.
For both sizes of post space, bond strengths dramatically decreased when fibre posts were inserted. There were no significant differences in microtensile bond strength between 1.5 mm and 1.75 mm canal width, regardless of fibre post insertion. Regional differences in bond strength were found only in the resin-filled canals.
The increase of C-factor of the root canal system by insertion of a fibre post had a detrimental effect on the bond strength to root canal dentine. On the other hand, the change of resin volume had no significant effect on bonding.
本研究旨在评估 C 因素和树脂体积对双固化黏结树脂对根管牙本质区域性黏结强度的影响。
12 颗单根人前磨牙被截冠并预备至 8mm 深,其中 6 颗的根管直径为 1.5mm,另外 6 颗为 1.75mm。根管牙本质用双固化黏结系统处理并用 20s 光固化。试件用双固化树脂复合材料填充,有或无插入 1.4mm 直径透光玻璃纤维桩,然后从冠方方向用 60s 光固化。水储存 24h 后,每个试件被连续切成 8 个 0.6mm×0.6mm 厚的薄片用于微拉伸黏结强度测试。使用 SEM 观察失效模式。将黏结强度数据分为冠部和根尖部进行统计分析。
对于两种大小的桩腔,插入纤维桩后黏结强度显著降低。无论插入纤维桩与否,1.5mm 和 1.75mm 根管宽度之间的微拉伸黏结强度没有显著差异。仅在树脂填充的根管中发现区域性黏结强度差异。
通过插入纤维桩增加根管系统的 C 因素对根管牙本质的黏结强度有不利影响。另一方面,树脂体积的变化对黏结没有显著影响。