Krieger Elena, Seiferth Jörg, Saric Ivana, Jung Britta A, Wehrbein Heinrich
Department of Orthodontics, University Medical Center of the Johannes Gutenberg University, Mainz, Germany.
J Orofac Orthop. 2011 Mar;72(2):141-9. doi: 10.1007/s00056-011-0017-4.
To analyse (a) to what extent the pretreatment model at the beginning of the treatment corresponds to the initial position in the ClinCheck® and (b) to what extent the predicted treatment result corresponds to the actual result of the therapy at the end of the treatment.
Pre- and posttreatment models as well as the initial and final position of the ClinCheck with a total of 35 patients aged between 15 and 59 were measured; all of whom were treated by using the Invisalign® technology (Invisalign®, Align Technology, S.C., Calif., USA). The measurement of the initial and final models was conducted by using an electronic digital calliper rule, i.e. that of ClinCheck® using the measurement tool ToothMeasure® of Invisalign® Software. The following parameters in the anterior region were measured: Overjet, Overbite, dental midline shift.
Pretreament models and the initial ClinChecks® revealed slight deviations in the parameters overjet 0.08 mm (standard deviation (SD) 0.3), overbite 0.3 mm (SD 0.4) and dental midline deviation 0.1mm (SD 0.4). The final model and the final ClinCheck® revealed larger deviations: the differences for the Overjet were on average 0.4 mm (SD 0.7), Overbite 0.9 mm (SD 0.9) and dental midline shift 0.4 mm (SD 0.5).
The IT-based transmission of mal-aligned teeth into the ClinCheck® presentation provides sufficiently good accuracy. Tooth corrections in the vertical plane were more difficult to realize. A vertical overcorrection in the final ClinCheck®, a case refinement at the end of the treatment or additional measures (e.g. horizontal beveled attachments or vertical elastics) seems useful to achieve the individually intended therapeutic goal.
分析(a)治疗开始时的预处理模型与ClinCheck®中的初始位置相符程度,以及(b)预测的治疗结果与治疗结束时的实际治疗结果相符程度。
测量了35例年龄在15至59岁之间患者的治疗前和治疗后模型以及ClinCheck®的初始和最终位置;所有患者均采用隐适美®技术(隐适美®,Align Technology,S.C.,加利福尼亚州,美国)进行治疗。初始和最终模型的测量使用电子数字卡尺,即ClinCheck®的测量使用隐适美®软件的ToothMeasure®测量工具。测量了前部区域的以下参数:覆盖、覆合、牙中线偏移。
治疗前模型与初始ClinCheck®显示在覆盖参数上有0.08毫米的轻微偏差(标准差(SD)0.3),覆合0.3毫米(SD 0.4),牙中线偏差0.1毫米(SD 0.4)。最终模型与最终ClinCheck®显示出更大的偏差:覆盖的差异平均为0.4毫米(SD 0.7),覆合0.9毫米(SD 0.9),牙中线偏移0.4毫米(SD 0.5)。
基于信息技术将排列不齐的牙齿传输到ClinCheck®呈现中具有足够好的准确性。垂直平面上的牙齿矫正更难实现。在最终ClinCheck®中进行垂直过度矫正、在治疗结束时进行病例细化或采取额外措施(如水平斜面附件或垂直弹力线)似乎有助于实现个体化的预期治疗目标。