Suppr超能文献

义齿基托树脂的力学性能:一项评估。

Mechanical properties of denture base resins: an evaluation.

作者信息

Chand Pooran, Patel Chandra Bhusan Singh, Singh Balendra Pratap, Singh Raghuwar Dayal, Singh Kamleshwar

机构信息

Department of Prosthodontics and Dental Material Sciences, Faculty of Dental Sciences, CSM Medical University, Lucknow, India.

出版信息

Indian J Dent Res. 2011 Jan-Feb;22(1):180. doi: 10.4103/0970-9290.79997.

Abstract

BACKGROUND

Acrylic resin dentures are susceptible to fracture after clinical use, which is a problem of concern in prosthodontics. Impact failure outside the mouth and flexure fatigue failure in the mouth are two most important causes of fracture of denture base.

AIM

This study evaluated the transverse deflection and transverse strength of four commercial brands of heat cure acrylic resin (Stellon, Acrylin-H, Trevalon and Trevalon-HI).

MATERIALS AND METHODS

An experimental design was adapted. Twenty-four rectangular strip specimens, six for each group, were prepared. Strips were finished on the edges and equally from the both the molded surfaces to make strips of specific dimensions. The tests were conducted mainly in accordance with the American Dental Association Specification no. 12/ISO: 1567-1981 (ISO: 6887-1986) for denture base polymer. The transverse deflection and transverse strength were measured by Instron testing machine. Intergroup differences were assessed using student "t" test.

RESULTS

The heat cure denture base material D (Trevalon "HI") had the minimum mean value of transverse deflection under different loads. Trevalon "HI" also had minimum value of mean transverse strength among different brands of acrylic resins. There was no statistically significant variation between Stellon, Acrylin-H and Trevalon, but variation was significantly higher with D (Trevalon "HI") vs. Stellon, Acrylin-H and Trevalon.

CONCLUSION

The heat cure denture base material D (Trevalon "HI") was the strongest and C (Trevalon) was the weakest among all materials used in this study. The study showed that the deflection of various denture base resins (A to D) increases proportionately with the increase in load.

摘要

背景

临床使用后,丙烯酸树脂假牙容易发生断裂,这是口腔修复学中一个备受关注的问题。假牙基托在口外的冲击破坏和在口内的弯曲疲劳破坏是假牙基托断裂的两个最重要原因。

目的

本研究评估了四种商业品牌热固化丙烯酸树脂(Stellon、Acrylin-H、Trevalon和Trevalon-HI)的横向挠度和横向强度。

材料与方法

采用实验设计。制备了24个矩形条试样,每组6个。对条带的边缘进行加工,并从两个成型表面均匀加工,以制成特定尺寸的条带。测试主要按照美国牙科协会第12号规范/ISO:1567-1981(ISO:6887-1986)对假牙基托聚合物的要求进行。通过英斯特朗试验机测量横向挠度和横向强度。使用学生“t”检验评估组间差异。

结果

热固化假牙基托材料D(Trevalon“HI”)在不同载荷下的横向挠度平均值最小。在不同品牌的丙烯酸树脂中,Trevalon“HI”的平均横向强度值也最小。Stellon、Acrylin-H和Trevalon之间没有统计学上的显著差异,但D(Trevalon“HI”)与Stellon、Acrylin-H和Trevalon之间的差异显著更大。

结论

在本研究使用的所有材料中,热固化假牙基托材料D(Trevalon“HI”)最强,C(Trevalon)最弱。研究表明,各种假牙基托树脂(A至D)的挠度随载荷增加而成比例增加。