Suppr超能文献

双膝大小相同吗?对289例双侧膝关节置换术的假体不对称性分析。

Are both the knees of the same size? Analysis of component asymmetry in 289 bilateral knee arthroplasties.

作者信息

Reddy Venkata Gurava, Mootha Aditya Krishna, Thayi Chiranjeevi, Kantesaria Pareen, Kumar Ramireddy Vinodh, Reddy Divakar

机构信息

Department of Orthopedics, Sunshine Hospitals, Secunderabad, Andhra Pradesh, India.

出版信息

Indian J Orthop. 2011 May;45(3):251-4. doi: 10.4103/0019-5413.80044.

Abstract

BACKGROUND

Variations in the anatomy of knee are well described, however the true incidence of component asymmetry in bilateral total knee arthroplsties is rarely reported. Incidence of component asymmetry in bilateral total knee arthroplasties (TKA) was retrospectively analysed in 289 cruciate retaining total knee arthroplasties.

MATERIALS AND METHODS

Medical records of these 289 patients were evaluated for the incidence of asymmetry of either femoral or tibial components. Clinical outcomes were compared between the cases of asymetrical components to that of symmetrical components.

RESULTS

Incidence of femoral component asymmetry was found to be 9.2% and tibial component asymmetry to be 8.7%. Of 289 cases, TKA 178 were done in a single day (group A), while 111 were done at 2- to 3-day intervals (group B). Asymmetric and symmetric knees were equally distributed among both groups, male and female patients in both groups, and the incidence of component asymmetry was similar between all four different implants - Optetrak-CR (Exactech, Gainesville, FL, USA), Nexgen-CR (Zimmer, Warsaw, IN, USA), PFC-Sigma CR (DePuy, Warsaw, IN, USA), Genesis II CR (Smith and Nephew, Memphis, TN, USA) we used. The pre- and postoperative range of motion and pre- and postoperative knee society scores were compared between the symmetric and asymmetric cases in both the groups and the difference was found to be insignificant.

CONCLUSION

We conclude that incidence of component asymmetry in bilateral total knee arthroplasty is around 9 % and independent sizing of both knees during bilateral arthoplasty is recommended rather than simply relying on the contralateral knee measurements.

摘要

背景

膝关节解剖结构的变异已有详细描述,然而双侧全膝关节置换术中假体不对称的真实发生率鲜有报道。对289例保留交叉韧带的全膝关节置换术患者的双侧全膝关节置换术中假体不对称的发生率进行了回顾性分析。

材料与方法

评估这289例患者的病历,以确定股骨或胫骨假体不对称的发生率。将假体不对称病例与对称病例的临床结果进行比较。

结果

发现股骨假体不对称的发生率为9.2%,胫骨假体不对称的发生率为8.7%。在289例病例中,178例全膝关节置换术在同一天完成(A组),而111例在2至3天的间隔内完成(B组)。不对称和对称膝关节在两组、两组的男性和女性患者中分布均匀,并且在我们使用的所有四种不同假体(美国佛罗里达州盖恩斯维尔Exactech公司的Optetrak-CR、美国印第安纳州华沙Zimmer公司的Nexgen-CR、美国印第安纳州华沙DePuy公司的PFC-Sigma CR、美国田纳西州孟菲斯史赛克公司的Genesis II CR)中,假体不对称的发生率相似。比较了两组中对称和不对称病例的术前和术后活动范围以及术前和术后膝关节协会评分,发现差异不显著。

结论

我们得出结论,双侧全膝关节置换术中假体不对称的发生率约为9%,建议在双侧关节成形术中对双膝进行独立测量,而不是简单地依赖对侧膝关节的测量。

相似文献

2
Component asymmetry in simultaneous bilateral total knee arthroplasty.
J Arthroplasty. 2006 Aug;21(5):749-53. doi: 10.1016/j.arth.2005.09.010.
3
Comparison of patient-reported outcomes based on implant brand in total knee arthroplasty: a prospective cohort study.
Bone Joint J. 2019 Jul;101-B(7_Supple_C):48-54. doi: 10.1302/0301-620X.101B7.BJJ-2018-1382.R1.
5
7
Comparison of Posterior Cruciate-Retaining and High-Flexion Cruciate-Retaining Total Knee Arthroplasty Design.
J Arthroplasty. 2020 Mar;35(3):752-755. doi: 10.1016/j.arth.2019.10.008. Epub 2019 Oct 10.
8
Implant design influences tibial post wear damage in posterior-stabilized knees.
Clin Orthop Relat Res. 2011 Jan;469(1):160-7. doi: 10.1007/s11999-010-1515-1.
9
Posterior-stabilized versus cruciate-retaining total knee arthroplasty: balancing the gap.
J Arthroplasty. 2002 Oct;17(7):813-9. doi: 10.1054/arth.2002.34814.
10
Average and peak contact stress distribution evaluation of total knee arthroplasties.
J Arthroplasty. 1996 Dec;11(8):952-63. doi: 10.1016/s0883-5403(96)80137-9.

引用本文的文献

1
Does commonly used femoral components of total knee arthroplasty fit well in the Indian population?
J Clin Orthop Trauma. 2024 Jun 7;53:102436. doi: 10.1016/j.jcot.2024.102436. eCollection 2024 Jun.
2
Component Asymmetry in Bilateral Cementless Total Hip Arthroplasty.
Clin Orthop Surg. 2023 Feb;15(1):27-36. doi: 10.4055/cios22028. Epub 2022 Aug 9.
3
The effect of implant size difference on patient outcomes and failure after bilateral simultaneous total knee arthroplasty.
J Orthop. 2020 Jun 13;22:282-287. doi: 10.1016/j.jor.2020.06.009. eCollection 2020 Nov-Dec.
5
Analysis of Interlimb Asymmetry in Patients Undergoing Simultaneous Bilateral Total Knee Arthroplasty.
PLoS One. 2015 Jun 24;10(6):e0129783. doi: 10.1371/journal.pone.0129783. eCollection 2015.

本文引用的文献

1
Patellofemoral overstuff and its relationship to flexion after total knee arthroplasty.
Clin Orthop Relat Res. 2006 Aug;449:283-7. doi: 10.1097/01.blo.0000218756.89439.06.
2
Component asymmetry in simultaneous bilateral total knee arthroplasty.
J Arthroplasty. 2006 Aug;21(5):749-53. doi: 10.1016/j.arth.2005.09.010.
5
Rationale of the Knee Society clinical rating system.
Clin Orthop Relat Res. 1989 Nov(248):13-4.