Sabbahi M A, Khalil M
School of Physical Therapy, Texas Women's University, Houston 77030.
Arch Phys Med Rehabil. 1990 Mar;71(3):223-7.
The H-reflex was recorded from the flexor carpi radialis, vastus medialis, and soleus muscles in patients with radiculopathy at C7, L4, and S1 roots. Reflex parameters were compared to normal standards and correlated with other electrophysiologic (eg, electromyography) and clinical evaluations, as well as magnetic resonance imaging scan reports. The H-reflex had significantly smaller peak-to-peak amplitude and longer latency. The stimulus threshold for eliciting the reflexes was substantially higher than normal standards, and the reflex was polyphasic in most patients. A strong correlation was recorded between the pathologic changes in reflex parameters and electrophysiologic and clinical findings of different segmental lesions. Magnetic resonance imaging reports showed moderate correlation with the H-reflex changes. A test of specificity showed that soleus and vastus medialis H-reflexes were 100% specific for lumbosacral segments; flexor carpi radialis was 90% specific for cervical spinal segments. These results indicate that flexor carpi radialis, vastus medialis, and soleus H-reflexes are useful and valid methods for testing C7, L4, and S1 radiculopathy.
在患有C7、L4和S1神经根病的患者中,从桡侧腕屈肌、股内侧肌和比目鱼肌记录Hoffmann反射(H反射)。将反射参数与正常标准进行比较,并与其他电生理检查(如肌电图)、临床评估以及磁共振成像扫描报告相关联。H反射的峰峰值幅度明显较小,潜伏期较长。引发反射的刺激阈值显著高于正常标准,并且在大多数患者中反射呈多相性。反射参数的病理变化与不同节段性病变的电生理和临床结果之间存在很强的相关性。磁共振成像报告显示与H反射变化存在中度相关性。特异性测试表明,比目鱼肌和股内侧肌的H反射对腰骶节段的特异性为100%;桡侧腕屈肌对颈髓节段的特异性为90%。这些结果表明,桡侧腕屈肌、股内侧肌和比目鱼肌的H反射是检测C7、L4和S1神经根病的有用且有效的方法。