Properties of the target registration error for surface matching in neuronavigation.

作者信息

Wang Man Ning, Song Zhi Jian

机构信息

Digital Medical Research Center of Shanghai Medical College, Fudan University, China.

出版信息

Comput Aided Surg. 2011;16(4):161-9. doi: 10.3109/10929088.2011.579791. Epub 2011 Jun 1.


DOI:10.3109/10929088.2011.579791
PMID:21631164
Abstract

OBJECTIVE: Surface matching is a relatively new method of spatial registration in neuronavigation. Compared to the traditional point matching method, surface matching does not use fiducial markers that must be fixed to the surface of the head before image scanning, and therefore does not require an image acquisition specifically dedicated for navigation purposes. However, surface matching is not widely used clinically, mainly because there is still insufficient knowledge about its application accuracy. This study aimed to explore the properties of the Target Registration Error (TRE) of surface matching in neuronavigation. MATERIALS AND METHODS: The surface matching process was simulated in the image space of a neuronavigation system so that the TRE could be calculated at any point in that space. For each registration, two point clouds were generated to represent the surface extracted from preoperative images (PC(image)) and the surface obtained intraoperatively by laser scanning (PC(laser)). The properties of the TRE were studied by performing multiple registrations with PC(laser) point clouds at different positions and generated by adding different types of error. RESULTS: For each registration, the TRE had a minimal value at a point in the image space, and the iso-valued surface of the TRE was approximately ellipsoid with smaller TRE on the inner surfaces. The position of the point with minimal TRE and the shape of the iso-valued surface were highly random across different registrations, and the surface registration error between the two point clouds was irrelevant to the TRE at a specific point. The overall TRE tended to increase with the increase in errors in PC(laser), and a larger PC(laser) made it less sensitive to these errors. With the introduction of errors in PC(laser), the points with minimal TRE tended to be concentrated in the anterior and inferior part of the head. CONCLUSION: The results indicate that the alignment between the two surfaces could not provide reliable information about the registration accuracy at an arbitrary target point. However, according to the spatial distribution of the target registration error of a single registration, enough application accuracy could be guaranteed by proper visual verification after registration. In addition, surface matching tends to achieve high accuracy in the inferior and anterior part of the head, and a relatively large scanning area is preferable.

摘要

相似文献

[1]
Properties of the target registration error for surface matching in neuronavigation.

Comput Aided Surg. 2011

[2]
Distribution templates of the fiducial points in image-guided neurosurgery.

Neurosurgery. 2010-3

[3]
Anatomical landmarks for point-matching registration in image-guided neurosurgery.

Int J Med Robot. 2013-6-3

[4]
Predicting error in rigid-body point-based registration.

IEEE Trans Med Imaging. 1998-10

[5]
A new markerless patient-to-image registration method using a portable 3D scanner.

Med Phys. 2014-10

[6]
Fiducial versus nonfiducial neuronavigation registration assessment and considerations of accuracy.

Neurosurgery. 2008-3

[7]
[Registration using three-dimensional laser surface scanning for navigation in oral and craniomaxillofacial surgery].

Zentralbl Chir. 2003-7

[8]
[Image-guided surgery for epilepsy].

No Shinkei Geka. 1997-4

[9]
Application accuracy in frameless image-guided neurosurgery: a comparison study of three patient-to-image registration methods.

J Neurosurg. 2007-6

[10]
Geometrical analysis of registration errors in point-based rigid-body registration using invariants.

Med Image Anal. 2010-8-10

引用本文的文献

[1]
Role of Virtual iMRI in Glioblastoma Surgery: Advantages, Limitations, and Correlation with iCT and Brain Shift.

Brain Sci. 2024-12-31

[2]
Deep Learning-Based Fine-Tuning Approach of Coarse Registration for Ear-Nose-Throat (ENT) Surgical Navigation Systems.

Bioengineering (Basel). 2024-9-20

[3]
Regional-surface-based registration for image-guided neurosurgery: effects of scan modes on registration accuracy.

Int J Comput Assist Radiol Surg. 2019-5-4

[4]
Neuronavigation-guided Frameless Stereoelectroencephalography (SEEG).

Neurol Med Chir (Tokyo). 2017-9-15

[5]
Recent advances in surgical planning & navigation for tumor biopsy and resection.

Quant Imaging Med Surg. 2015-10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具