The venous return simulator: comparison of simulated with measured ambulatory venous pressure in normal subjects and in venous valve incompetence.

作者信息

Chauveau M, Gelade P, Cros F

机构信息

Laboratoires INNOTHERA Arcueil, France.

出版信息

Vasa. 2011 May;40(3):205-17. doi: 10.1024/0301-1526/a000095.

DOI:10.1024/0301-1526/a000095
PMID:21638249
Abstract

BACKGROUND

To compare results of numerical simulation of lower limb venous return with those of in vivo measurements, in normal subjects, and those with venous incompetence.

PATIENTS AND METHODS

the venous return simulator (VRS) is a mathematical model which takes into account architecture, dimensions, and compliance of the venous network, blood viscosity, valve function, and external pressures (muscular contraction, compression stockings). Using the laws of hydrodynamics, it provides calibres, pressures and flows throughout the network. Ambulatory venous pressure (AVP) computed for some theoretical examples of superficial and /or deep venous incompetence has been compared to in vivo values reported in literature.

RESULTS

In a normal subject, computed AVP was 33 mmHg during walking and 30 mmHg with tiptoe exercise; the range of conventionally measured AVP is 20.6 - 27.9 mmHg during walking, and 29 - 32.5 mmHg during tiptoe exercise; In the case of great saphenous vein (GSV) incompetence, computed AVP was 34 or 57 mmHg, according to whether the distal GSV was competent or not. The range of AVP measured in superficial venous insufficiency is 27.6 - 61 mmHg, all but one of the published values lie between the low computed value corresponding to a short reflux and the high computed value due to a long distance reflux. AVP computed in two cases of deep venous incompetence was 44 and 71 mmHg, according to the extent of devalvulation, as compared with the 60 mmHg reported in one clinical study In patients with extensive combined incompetence, computed AVP was 75 mmHg, whilst the range of conventionally measured values was between 62 and 84 mmHg.

CONCLUSIONS

the good agreement between computed and measured AVP in different cases of valve incompetence indicates that the VRS is quite a realistic model, with the potential to simulate the results of surgery or compression therapy.

摘要

相似文献

1
The venous return simulator: comparison of simulated with measured ambulatory venous pressure in normal subjects and in venous valve incompetence.
Vasa. 2011 May;40(3):205-17. doi: 10.1024/0301-1526/a000095.
2
Descending phlebography in patients with venous ulceration: hemodynamic implications.静脉溃疡患者的下行静脉造影:血流动力学影响
Int Angiol. 2015 Jun;34(3):263-8. Epub 2015 Apr 16.
3
The venous return simulator: an effective tool for investigating the effects of external compression on the venous hemodynamics--first results after thigh compression.静脉回流模拟器:一种用于研究外部压迫对静脉血流动力学影响的有效工具——大腿压迫后的初步结果
Vasa. 2005 Feb;34(1):19-23. doi: 10.1024/0301-1526.34.1.19.
4
Comparison of new continuous measurements of ambulatory venous pressure (AVP) with conventional tiptoe exercise ambulatory AVP in relation to the CEAP clinical classification of chronic venous disease.动态静脉压(AVP)新的连续测量值与传统踮脚尖运动动态AVP在慢性静脉疾病CEAP临床分级方面的比较。
J Vasc Surg. 2006 Oct;44(4):794-802. doi: 10.1016/j.jvs.2006.06.007.
5
Failure of microvenous valves in small superficial veins is a key to the skin changes of venous insufficiency.小浅静脉中小静脉瓣膜的失效是静脉功能不全皮肤改变的关键。
J Vasc Surg. 2011 Dec;54(6 Suppl):62S-9S.e1-3. doi: 10.1016/j.jvs.2011.06.085. Epub 2011 Sep 13.
6
High compression pressure over the calf is more effective than graduated compression in enhancing venous pump function.小腿高压比梯度压力更能有效地增强静脉泵功能。
Eur J Vasc Endovasc Surg. 2012 Sep;44(3):332-6. doi: 10.1016/j.ejvs.2012.06.001. Epub 2012 Jul 21.
7
Conception of the venous hemodynamics in the lower extremity.下肢静脉血流动力学的概念。
Angiology. 2006 Oct-Nov;57(5):556-63. doi: 10.1177/0003319706293117.
8
Ultrasonographic assessment of ambulatory venous pressure in superficial venous incompetence.超声评估浅静脉功能不全患者的动态静脉压
J Vasc Surg. 1997 Nov;26(5):796-802. doi: 10.1016/s0741-5214(97)70092-2.
9
Ambulatory venous pressure measurements: new parameters derived from a mathematic hemodynamic model.
J Vasc Surg. 2002 Jul;36(1):137-42. doi: 10.1067/mva.2002.124622.
10
Endovenous laser treatment combined with a surgical strategy for treatment of venous insufficiency in lower extremity: a report of 208 cases.腔内激光治疗联合手术策略治疗下肢静脉功能不全:208例报告
J Vasc Surg. 2005 Sep;42(3):494-501; discussion 501. doi: 10.1016/j.jvs.2005.02.051.

引用本文的文献

1
Dogmas and controversies in compression therapy: report of an International Compression Club (ICC) meeting, Brussels, May 2011.压迫治疗的教条和争议:国际压迫俱乐部(ICC)会议报告,2011 年 5 月,布鲁塞尔。
Int Wound J. 2013 Oct;10(5):516-26. doi: 10.1111/j.1742-481X.2012.01009.x. Epub 2012 Jun 21.