Green Technology Research Center, Department of Chemical and Materials Engineering, Chang Gung University, 259 Wen-Hwa 1st Rd., Kuei-Shan, Tao-Yuan 33302, Taiwan, ROC.
Talanta. 2011 Jul 15;85(1):631-7. doi: 10.1016/j.talanta.2011.04.038. Epub 2011 Apr 16.
The imine of polybenzimidazole (PBI) is chemically oxidized by hydrogen peroxide (H(2)O(2)) in the presence of acetic acid (AcOH). Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopies (XPS) showed that when the AcOH concentration remained constant, the degree of oxidation increased with increasing H(2)O(2) levels. Moreover, the imine also exhibited electrochemical redox behavior. Based on these properties, a PBI-modified Au (PBI/Au) electrode was developed as an enzyme-free H(2)O(2) sensor. At an applied potential of -0.5V vs. Ag/AgCl, the current response of the PBI/Au electrode was linear with H(2)O(2) concentration over a range from 0.075 to 1.5mM, with a sensitivity of 55.0 μA mM(-1)cm(-2). The probe had excellent stability, with <5% variation from its initial response current after storage at 50°C for 10 days. Potentially interfering species such as ascorbic or uric acid had no effect on sensitivity. Sensitivity improved dramatically when multiwalled carbon nanotubes (MWCNT) were incorporated in the probe. Under optimal conditions, the detection of H(2)O(2) using a MWCNT-PBI/Au electrode was linear from 1.56 μM to 2.5mM, with a sensitivity of 928.6 μA mM(-1)cm(-2). Analysis of H(2)O(2) concentrations in urine samples using a MWCNT-PBI/Au electrode produced accurate real-time results comparable to those of traditional HPLC methods.
聚亚苯并咪唑(PBI)的亚胺在醋酸(AcOH)存在下被过氧化氢(H2O2)化学氧化。傅里叶变换红外(FT-IR)和 X 射线光电子能谱(XPS)表明,当 AcOH 浓度保持不变时,氧化程度随 H2O2 水平的增加而增加。此外,亚胺还表现出电化学氧化还原行为。基于这些特性,开发了一种 PBI 修饰的 Au(PBI/Au)电极作为无酶 H2O2 传感器。在相对于 Ag/AgCl 的-0.5V 施加电位下,PBI/Au 电极的电流响应与 H2O2 浓度在 0.075 至 1.5mM 的范围内呈线性关系,灵敏度为 55.0 μA mM(-1)cm(-2)。该探针具有出色的稳定性,在 50°C 下储存 10 天后,其初始响应电流的变化小于 5%。潜在的干扰物质,如抗坏血酸或尿酸,对灵敏度没有影响。当将多壁碳纳米管(MWCNT)掺入探针中时,灵敏度会显著提高。在最佳条件下,使用 MWCNT-PBI/Au 电极检测 H2O2 的线性范围为 1.56 μM 至 2.5mM,灵敏度为 928.6 μA mM(-1)cm(-2)。使用 MWCNT-PBI/Au 电极分析尿液样品中的 H2O2 浓度可产生准确的实时结果,与传统 HPLC 方法相当。