Suppr超能文献

腋动脉导管使用与多发创伤患者手部缺血相关:病例报告与文献复习。

Axillary arterial catheter use associated with hand ischemia in a multi-trauma patient: case report and literature review.

机构信息

Washington University School of Medicine, Saint Louis, MO 63110, USA.

出版信息

J Clin Anesth. 2011 Jun;23(4):325-8. doi: 10.1016/j.jclinane.2010.07.006.

Abstract

A case of hand ischemia associated with use of an axillary arterial catheter in a multi-trauma patient is presented. Despite removal of the arterial catheter and limb salvage procedures, distal hand gangrene developed. Simple measures such as minimizing dressings, use of distal continuous pulse oximetry, placement of invasive arterial catheters in the nondominant extremity, and avoiding their use whenever possible may prevent complications and minimize morbidity.

摘要

现报道 1 例多创伤患者使用腋动脉导管导致手部缺血的病例。尽管移除了动脉导管并进行了肢体保全手术,但仍发展为手部远端坏疽。简单的措施,如尽量减少敷料、使用远端连续脉搏血氧饱和度监测、将有创动脉导管放置在非优势肢体上并尽可能避免使用,可能预防并发症并使发病率降至最低。