Analytical Chemistry, Department of Physical and Analytical Chemistry, Uppsala University, Uppsala, Sweden.
Electrophoresis. 2011 Jun;32(13):1778-85. doi: 10.1002/elps.201100121.
In this study, the extraction recoveries of an anticancer drug (Imatinib) from human plasma using a common liquid-liquid extraction (LLE) method and a new strong cation exchange (SCX) solid-phase extraction (SPE) column was investigated. The extracts were analyzed with CE coupled on-line to electrospray ionization (ESI) time-of-flight mass spectrometry (TOF-MS) using a monoquaternarized piperazine compound (M7C4I) for capillary coatings. Clean extracts with high and reproducible extraction recoveries ranging between 85 and 91% with % RSD values of 2.5% (n = 3) were obtained using the SCX-SPE columns. This can be compared with the recoveries obtained with the LLE method ranging between 30 and 35%. The CE-ESI-TOF-MS analysis was performed in <10 min with peak efficiencies up to 4.7 × 10⁵ plates/m and an average % RSD for the repeatability of the migration times of the analytes of 1.9% (n = 3) using acidic buffer and adding 5% ACN to the sample. The calibration curves were linear over the range of 0-1500 ng/mL with correlation coefficient (R² ≥ 0.997 and % RSD values of 0.5% (n=3). The intra-day and inter-day assay variations were lower than 8%. The presented CE-ESI-TOF-MS method with the use of SCX-SPE columns yielded rapid, efficient and high extraction recoveries together with high sensitivity (LOD 5 ng/mL), selectivity and good linearity. Accordingly, the method can readily be used for accurate determination and therapeutic monitoring of the Imatinib blood levels for more effective patient treatment. In addition, it can be applied for the extraction, quantification and clinical assessments of metabolites of Imatinib and other basic pharmaceutical drug molecules in biological fluids or pharmaceutical dosage forms.
在这项研究中,考察了一种常用的液液萃取(LLE)方法和一种新型强阳离子交换(SCX)固相萃取(SPE)柱从人血浆中提取抗癌药物(伊马替尼)的萃取回收率。采用单季铵化哌嗪化合物(M7C4I)对毛细管涂层进行在线 CE 与电喷雾电离(ESI)飞行时间质谱(TOF-MS)联用,对提取物进行分析。使用 SCX-SPE 柱可获得具有高回收率和重现性的清洁提取物,回收率在 85%至 91%之间,%RSD 值为 2.5%(n=3)。这可以与 LLE 方法获得的回收率进行比较,回收率在 30%至 35%之间。CE-ESI-TOF-MS 分析在 <10 分钟内完成,峰效率高达 4.7×10⁵ 板/m,使用酸性缓冲液和向样品中添加 5%ACN 时,分析物迁移时间重复性的平均%RSD 为 1.9%(n=3)。校准曲线在 0-1500 ng/mL 范围内呈线性,相关系数(R²≥0.997),%RSD 值为 0.5%(n=3)。日内和日间测定变异均低于 8%。使用 SCX-SPE 柱的 CE-ESI-TOF-MS 方法快速、高效、高萃取回收率,同时具有高灵敏度(LOD 5ng/mL)、选择性和良好的线性。因此,该方法可用于准确测定和治疗监测伊马替尼的血液水平,以实现更有效的患者治疗。此外,它还可用于从生物体液或药物制剂中提取、定量和临床评估伊马替尼和其他基本药物分子的代谢物。