Oakland Bone and Joint Specialist, Orthopedic Surgery, 80 Grand Avenue, 5th floor, Oakland, CA 94612, USA.
Foot Ankle Int. 2011 May;32(5):S473-84. doi: 10.3113/FAI.2011.0473.
There has been a resurgence of interest in total ankle replacement (TAR) due to improved results with newer prostheses. However, long-term survivorship data has been limited. The STAR™ Ankle prosthesis is the first three-part prosthesis approved for use in the United States.
Eighty-four total ankle replacements were performed in 80 patients using the STAR™ Ankle prosthesis and followed prospectively. Postoperatively, patients were evaluated with the AOFAS score for pain and function, and serial radiographs were evaluated for stability and alignment of the prosthesis. Implant failure, secondary procedures, and complications were recorded.
Ninety-one percent of prostheses remain implanted at an average followup of 9.1 years. The probability of implant survival was 96% at 5 years and 90% at 10 years. An average 39-point improvement in the AOFAS ankle-hindfoot score was noted, from a mean of 43 to a mean of 82 points. We noted a statistically significant increase in both average pain and function sub-scores. Postoperative range of motion averaged 4.5 degrees of dorsiflexion and 35 degrees of plantarflexion. Ninety-two percent of the patients were satisfied with their outcome. Ten patients (13%) developed concerning osteolytic lesions. Change in prosthetic alignment and adjacent joint arthritis were similar to previous reports. We report 21 complications, which included 14 additional surgical procedures.
The first U.S. prospective long-term survivorship data with the STAR™ Ankle prosthesis found it to be an excellent long-term option for the treatment of ankle arthritis.
由于新型假体的结果得到改善,全踝关节置换术(TAR)的兴趣再次兴起。然而,长期生存数据有限。STAR™踝关节假体是美国批准使用的首个三部分假体。
使用 STAR™踝关节假体对 80 例 80 名患者进行了 84 例全踝关节置换术,并进行了前瞻性随访。术后采用 AOFAS 评分评估疼痛和功能,连续拍摄 X 线片评估假体的稳定性和对线。记录植入物失败、二次手术和并发症。
91%的假体在平均 9.1 年的随访中仍植入。5 年和 10 年的假体存活率分别为 96%和 90%。AOFAS 踝关节-后足评分平均提高 39 分,从平均 43 分提高到平均 82 分。我们注意到平均疼痛和功能子评分均有统计学显著提高。术后平均背屈活动度为 4.5 度,跖屈活动度为 35 度。92%的患者对其结果感到满意。10 名患者(13%)出现令人担忧的溶骨性病变。假体对线和相邻关节关节炎的变化与之前的报告相似。我们报告了 21 种并发症,包括 14 种额外的手术。
STAR™踝关节假体在美国的首批前瞻性长期生存数据显示,它是治疗踝关节关节炎的一种极好的长期选择。