BACKGROUND

Initial results on the application of the water-jet in a parotidectomy setting in an animal study demonstrate that there are morphologic changes which do, and some which do not, affect the clinial function of the facial nerve due to the different jet sizes and operating pressures used. In a further study the histomorphometric data of the facial nerve dissected by the water-jet should be evaluated and correlated to the different sizes of jet and operating pressures.

MATERIAL AND METHODS

In total, 102 nerves (in 14 beagles) which had been dissected by water-jets of different sizes and operating pressures were evaluated. After an observation period of 21 days, including documentation of the clinical function of the facial nerve, the nerves were dissected. The number of nerve fibers and the diameter of the different nerve fibers were then evaluated.

RESULTS

All nerve fibers dissected with jet sizes of 120 and 150 μm showed an identical cumulative frequency of fiber diameters. All nerve fibers dissected with a water-jet of 200 μm showed morphologic and clinical abnormalities and--in terms of nerve fiber diameters--clear differences to the nerve fibers dissected with 120- or 150-μm jets. Altogether, there is a decrease in fiber diameter along the nerve course.

CONCLUSION

Our data show a shift of larger diameters of the nerve trunk to smaller diameters in the terminal nerve fibers. This phenomenon has not been described in the literature to date and is probably not due to the water-jet. Additionally, our data show that 22% of the original nerve fiber damaged by the water-jet is sufficient to preserve the nerve's clinical function.

摘要

背景

在一项动物研究中,水刀在腮腺切除术环境中的初步应用结果表明,由于使用的水刀尺寸和操作压力不同,存在一些影响面神经临床功能的形态学变化,也有一些不影响。在进一步的研究中,应评估用水刀解剖的面神经的组织形态计量学数据,并将其与不同的水刀尺寸和操作压力相关联。

材料与方法

总共评估了14只比格犬中102条被不同尺寸和操作压力的水刀解剖的神经。在21天的观察期后,包括记录面神经的临床功能,对神经进行解剖。然后评估神经纤维的数量和不同神经纤维的直径。

结果

用120和150μm尺寸水刀解剖的所有神经纤维显示出相同的纤维直径累积频率。用200μm水刀解剖的所有神经纤维均显示出形态学和临床异常,并且在神经纤维直径方面与用120或150μm水刀解剖的神经纤维有明显差异。总体而言,沿神经行程纤维直径减小。

结论

我们的数据显示神经干较大直径向终末神经纤维较小直径的转变。这种现象在迄今为止的文献中尚未被描述,并且可能不是由水刀导致的。此外,我们的数据表明,水刀损伤的原始神经纤维的22%足以保留神经的临床功能。