[剖宫产脊髓麻醉期间不同低血压预防措施产妇胎盘的体视学研究]

[Stereological study of the placenta in parturients with different prophylactic measures for hypotension during spinal anesthesia for cesarean section].

作者信息

Shuai Bing, Peng Xue-mei, Li Rui-man, Li Ya-lan, Hu Dong-hua

机构信息

Department of Anesthesiology, First Affiliated Hospital of Jinan University, Guangzhou 510630, China.

出版信息

Nan Fang Yi Ke Da Xue Xue Bao. 2011 Jun;31(7):1240-4.

Abstract

OBJECTIVE

To explore the optimal approach to the prevention of hypotension during cesarean section for the benefits of both the parturients and the newborns.

METHODS

Forty singleton full-term pregnant women undergoing elective cesarean delivery were randomly allocated into two equal groups. For prevention of hypotension during spinal anesthesia, ephedrine or pre-anesthetic volume with Voluven was administered. The changes of blood pressure, heart rate, and Apgar scores of the newborns were monitored and recorded, and the umbilical arterial blood gas variables were compared between the two groups. The placental samples were collected and immunohistochemistry for CD34 was performed for stereological study of the placental villous capillaries.

RESULTS

The umbilical arterial PaCO(2), PaO(2) and Apgar scores showed no significant differences between the two groups (P<0.05). The heart rate, incidence of hypotension and the lactic acid value were significantly higher, and the umbilical arterial pH significantly lower in ephedrine group than in the Voluven group (P>0.05). While the length density of the villous capillaries was comparable between the two groups (P>0.05), the volume density of the villous capillaries was significantly decreased in ephedrine group (P<0.05).

CONCLUSION

Pre-anesthetic volume expansion with Voluven can maintain stable hemodynamics during spinal anesthesia and also efficiently improve the tissue perfusion, microcirculation and uteroplacental blood flow, thus increasing the oxygen supply to the fetus.

摘要

目的

探讨剖宫产术中预防低血压的最佳方法,以造福产妇和新生儿。

方法

40例择期剖宫产的单胎足月孕妇被随机分为两组,每组人数相等。为预防脊麻期间的低血压,分别给予麻黄碱或用万汶进行麻醉前扩容。监测并记录血压、心率变化以及新生儿的阿氏评分,并比较两组脐动脉血气变量。收集胎盘样本,进行CD34免疫组化,对胎盘绒毛毛细血管进行体视学研究。

结果

两组脐动脉血二氧化碳分压(PaCO₂)、氧分压(PaO₂)及阿氏评分差异无统计学意义(P<0.05)。麻黄碱组心率、低血压发生率及乳酸值显著高于万汶组,脐动脉血pH值显著低于万汶组(P>0.05)。两组绒毛毛细血管长度密度差异无统计学意义(P>0.05),但麻黄碱组绒毛毛细血管体积密度显著降低(P<0.05)。

结论

麻醉前用万汶进行容量扩充可在脊麻期间维持血流动力学稳定,还能有效改善组织灌注、微循环及子宫胎盘血流,从而增加对胎儿的氧供。