为母亲适应证进行的计算机断层扫描多平面和三维重建在可视化胎儿解剖结构及估计孕周方面的效用。

Utility of multiplanar and three-dimensional reconstructions from computed tomography performed for maternal indications for visualizing fetal anatomy and estimating gestational age.

作者信息

Taneja Ranu, Dighe Manjiri, Kanal Kalpana M, Richardson Michael L, Mitsumori Lee M, Dubinsky Theodore J

机构信息

Department of Radiology, Changi General Hospital, Singapore, Singapore.

出版信息

J Comput Assist Tomogr. 2011 Jul-Aug;35(4):446-53. doi: 10.1097/RCT.0b013e3182206f40.

Abstract

OBJECTIVE

The purpose of this article was to determine the usefulness of multiplanar and 3-dimensional (3D) reconstructions of computed tomographic (CT) data from scans performed for maternal indications for visualizing fetal anatomy and estimating gestational age.

MATERIALS AND METHODS

Eighteen pregnant patients who had abdominopelvic CT scanning performed for maternal indications formed the study group. Two independent reviewers created multiplanar and 3D-reconstructed images of the fetus from these CT scans and analyzed them for fetal anatomy and gestational age. Fetal dose estimates were also obtained.

RESULTS

Computed tomographic fetal biometry generally agreed well with ultrasound estimates. Computed tomographic and ultrasound estimates were within 3 to 4 weeks of each other 95% of the time for the 2 reviewers. Pearson correlation coefficients were 0.989 for reviewer 1 and 0.985 for reviewer 2. Fetal anatomic survey revealed that it was easier to see bones and fluid-filled structures such as the stomach and urinary bladder than intracranial, intrathoracic, and intra-abdominal soft tissue structures. Estimated fetal dose was 28.5 (10.7) mGy using the Imaging Performance Assessment of CT Scanner calculator and 23.7 (7.7) mGy when taking maternal perimeter and fetal depth into account with the method of Angel et al.

CONCLUSIONS

It is technically feasible to produce clinically useful images of the fetus using standard multiplanar reconstructions and 3D algorithms already in place for CT scanning. As CT scans continue to be performed under certain circumstances, particularly the emergency department setting, evaluation of maternal CT scans for potentially useful information about the fetus such as gestational age and gross anatomic survey can be obtained at estimated fetal radiation doses much lower than the actionable level of 150 mGy.

摘要

目的

本文旨在确定针对母体指征进行的计算机断层扫描(CT)数据的多平面和三维(3D)重建在可视化胎儿解剖结构和估计孕周方面的实用性。

材料与方法

18例因母体指征接受腹部盆腔CT扫描的孕妇组成研究组。两名独立的审阅者从这些CT扫描中创建胎儿的多平面和3D重建图像,并对其进行胎儿解剖结构和孕周分析。同时还获得了胎儿剂量估计值。

结果

CT胎儿生物测量值与超声估计值总体上吻合良好。对于两位审阅者而言,CT和超声估计值在95%的时间内彼此相差3至4周。审阅者1的Pearson相关系数为0.989,审阅者2的为0.985。胎儿解剖结构检查显示,与颅内、胸腔内和腹腔内的软组织结构相比,骨骼以及胃和膀胱等充满液体的结构更容易看清。使用CT扫描仪成像性能评估计算器估计的胎儿剂量为28.5(10.7)mGy,采用Angel等人的方法考虑母体周长和胎儿深度时为23.7(7.7)mGy。

结论

使用CT扫描现有的标准多平面重建和3D算法生成临床上有用的胎儿图像在技术上是可行的。由于在某些情况下,特别是在急诊科环境中仍会进行CT扫描,因此在估计胎儿辐射剂量远低于150 mGy的可操作水平时,对母体CT扫描进行评估可获取有关胎儿的潜在有用信息,如孕周和大体解剖结构检查结果。