The National Center for Drug Screening and The State Key Laboratory of Drug Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China.
Anal Biochem. 2011 Nov 1;418(1):66-72. doi: 10.1016/j.ab.2011.06.040. Epub 2011 Jul 5.
To develop a real-time thallium flux assay for high-throughput screening (HTS) of human KCNQ4 (Kv7.4) potassium channel openers, we used CHO-K1 cells stably expressing human KCNQ4 channel protein and a thallium-sensitive dye based on the permeability of thallium through potassium channels. The electrophysiological and pharmacological properties of the cell line expressing the KCNQ4 protein were found to be in agreement with that reported elsewhere. The EC(50) values of the positive control compound (retigabine) determined by the thallium and (86)rubidium flux assays were comparable to and consistent with those documented in the literature. Signal-to-background (S/B) ratio and Z factor of the thallium influx assay system were assessed to be 8.82 and 0.63, respectively. In a large-scale screening of 98,960 synthetic and natural compounds using the thallium influx assay, 76 compounds displayed consistent KCNQ4 activation, and of these 6 compounds demonstrated EC(50) values of less than 20 μmol/L and 2 demonstrated EC(50) values of less than 1 μmol/L. Taken together, the fluorescence-based thallium flux assay is a highly efficient, automatable, and robust tool to screen potential KCNQ4 openers. This approach may also be expanded to identify and evaluate potential modulators of other potassium channels.
为了开发高通量筛选(HTS)人类 KCNQ4(Kv7.4)钾通道开放剂的实时铊通量测定法,我们使用稳定表达人 KCNQ4 通道蛋白的 CHO-K1 细胞和基于铊通过钾通道的通透性的铊敏感染料。表达 KCNQ4 蛋白的细胞系的电生理和药理学特性与别处报道的一致。阳性对照化合物(瑞替加滨)的 EC50 值通过铊和(86)铷通量测定法确定,与文献中记录的结果相当且一致。铊内流测定系统的信号与背景(S/B)比值和 Z 因子分别评估为 8.82 和 0.63。在使用铊内流测定法对 98960 种合成和天然化合物进行的大规模筛选中,有 76 种化合物显示出一致的 KCNQ4 激活作用,其中 6 种化合物的 EC50 值低于 20μmol/L,2 种化合物的 EC50 值低于 1μmol/L。总之,基于荧光的铊通量测定法是一种高效、自动化和强大的筛选潜在 KCNQ4 开放剂的工具。这种方法也可以扩展到鉴定和评估其他钾通道的潜在调节剂。