Department of Orthodontics, Faculty of Dentistry, University of Toronto, Toronto, Ontario, Canada.
Am J Orthod Dentofacial Orthop. 2011 Aug;140(2):e67-75. doi: 10.1016/j.ajodo.2011.02.017.
Rapid palatal expanders (RPEs) have attachments cemented to the teeth and a screw that covers the palate. Because of their position and relative size, RPEs can affect speech. Our objective was to assess speech perturbation and adaptation related to RPE appliances over time.
RPEs were planned for the treatment of 22 patients in the orthodontic clinic at the University of Toronto in Canada. Speech recordings were made at 6 time points: before RPE placement, after placement, during expansion, during retention, after removal, and 4 weeks after removal. The speech recordings consisted of 35 sentences, from which 3 sentences were chosen for analysis. Speech acceptability was assessed perceptually by 10 listeners who rated each sentence on an equal-appearing interval scale. The vowel formants for /i/ and the fricative spectra for /s/ and /∫/ were measured with speech analysis software. Repeated-measures analysis of variance with post-hoc paired t tests was used for statistical analysis.
When the appliance was placed, speech acceptability deteriorated. Over time, the ratings improved and returned to baseline when the appliance was removed. For the vowel /i/, the first formant increased, and the second formant decreased in frequency, indicating centralization of the vowel. The formants returned to the pretreatment levels during treatment. For the fricatives (/s/ and /∫/), low-to-high frequency ratios indicated that the fricatives were distorted when the appliance was placed. The ratios returned to baseline levels once the appliance was removed. The results for the spectral moments indicated that spectral mean decreased and skewness became more positive. Repeated-measures analysis of variance showed significant effects for time for all acoustic measures.
Speech was altered and distorted when the appliance was first placed. The patients' speech gradually improved over time and returned to baseline once the appliance was removed. The results from the study will be useful for pretreatment counseling of patients and their families.
快速腭扩张器 (RPE) 有附着在牙齿上的附件和覆盖在上颚的螺丝。由于它们的位置和相对大小,RPE 会影响发音。我们的目标是评估 RPE 矫治器随时间推移对语音的影响和适应情况。
加拿大多伦多大学正畸诊所计划使用 RPE 治疗 22 名患者。在 6 个时间点进行语音记录:放置 RPE 之前、放置之后、扩张期间、保持期间、拆除之后和拆除后 4 周。语音记录由 35 个句子组成,从中选择 3 个句子进行分析。语音可接受性通过 10 位听众进行感知评估,每位听众在等距量表上对每个句子进行评分。使用语音分析软件测量/i/的元音共振峰和/s/和/∫/的摩擦谱。采用重复测量方差分析和事后配对 t 检验进行统计分析。
放置矫治器时,语音可接受性恶化。随着时间的推移,评分逐渐改善,当矫治器拆除时恢复到基线水平。对于元音/i/,第一共振峰增加,第二共振峰频率降低,表明元音向中央化方向移动。在治疗过程中,共振峰恢复到治疗前的水平。对于摩擦音 (/s/和/∫/),低频到高频的比值表明放置矫治器时摩擦音发生了扭曲。一旦矫治器拆除,比值恢复到基线水平。谱矩的结果表明,谱均值降低,偏度变得更加正向。重复测量方差分析显示所有声学测量的时间均有显著影响。
矫治器首次放置时,语音发生了改变和扭曲。随着时间的推移,患者的语音逐渐改善,一旦矫治器拆除,语音恢复到基线水平。该研究的结果将有助于对患者及其家属进行治疗前咨询。