Management of glenohumeral arthrosis with a total shoulder prosthesis is becoming increasingly common. However, failure of the glenoid component remains one of the most common causes for failure. Our understanding of this problem has evolved greatly since the first implants were placed in the 1970's. However glenoid failure remains a challenging problem to address and manage. This article reviews the current knowledge regarding the glenoid in total shoulder arthroplasty touching on anatomy, component design, implant fixation, causes of implant failure, management of glenoid failure and alternatives to glenoid replacement.

摘要

全肩关节置换术治疗盂肱关节骨关节炎越来越常见。然而,肩胛盂部件的失败仍然是最常见的失败原因之一。自 20 世纪 70 年代首次植入以来,我们对这个问题的理解已经有了很大的发展。然而,肩胛盂的失败仍然是一个具有挑战性的问题需要解决和管理。本文回顾了全肩关节置换术中肩胛盂的现有知识,涉及解剖、部件设计、植入物固定、植入物失败的原因、肩胛盂失败的处理以及肩胛盂置换的替代方法。

相似文献

1
The glenoid in total shoulder arthroplasty.
Curr Rev Musculoskelet Med. 2011 Dec;4(4):191-9. doi: 10.1007/s12178-011-9096-5.
2
The glenoid in shoulder arthroplasty.
J Shoulder Elbow Surg. 2009 Sep-Oct;18(5):819-33. doi: 10.1016/j.jse.2009.05.008. Epub 2009 Jul 1.
3
The association between glenoid component design and revision risk in anatomic total shoulder arthroplasty.
J Shoulder Elbow Surg. 2020 Oct;29(10):2089-2096. doi: 10.1016/j.jse.2020.02.024. Epub 2020 Jun 5.
4
Glenoid component failure in total shoulder arthroplasty.
J Bone Joint Surg Am. 2008 Apr;90(4):885-96. doi: 10.2106/JBJS.G.01263.
6
The effect of glenohumeral radial mismatch on different augmented total shoulder arthroplasty glenoid designs: a finite element analysis.
J Shoulder Elbow Surg. 2019 Jun;28(6):1146-1153. doi: 10.1016/j.jse.2018.11.059. Epub 2019 Feb 13.
8
[Current status and perspectives of shoulder replacement].
Unfallchirurg. 1999 Sep;102(9):668-83. doi: 10.1007/s001130050465.
9
Revision arthroplasty with a hip-inspired computer-assisted design/computer-assisted manufacturing implant for glenoid-deficient shoulders.
J Shoulder Elbow Surg. 2014 Feb;23(2):205-13. doi: 10.1016/j.jse.2013.05.004. Epub 2013 Jul 10.
10
A comparison of onlay versus inlay glenoid component loosening in total shoulder arthroplasty.
J Shoulder Elbow Surg. 2017 Jul;26(7):1113-1120. doi: 10.1016/j.jse.2017.01.018. Epub 2017 Mar 27.

引用本文的文献

2
Convertible metal-backed glenoid in total shoulder arthroplasty.
Bone Jt Open. 2025 Jan 14;6(1):82-92. doi: 10.1302/2633-1462.61.BJO-2024-0118.R1.
5
Difference in glenoid retroversion between two-dimensional axial computed tomography and three-dimensional reconstructed images.
Clin Shoulder Elb. 2020 May 21;23(2):71-79. doi: 10.5397/cise.2020.00122. eCollection 2020 Jun.
6
Baseplate Options for Reverse Total Shoulder Arthroplasty.
Curr Rev Musculoskelet Med. 2020 Dec;13(6):769-775. doi: 10.1007/s12178-020-09677-1.
7
CT scan evaluation of glenoid bone and pectoralis major tendon: interest in shoulder prosthesis.
SICOT J. 2016;2:33. doi: 10.1051/sicotj/2016021. Epub 2016 Oct 7.
8
Porous metals and alternate bearing surfaces in shoulder arthroplasty.
Curr Rev Musculoskelet Med. 2016 Mar;9(1):59-66. doi: 10.1007/s12178-016-9319-x.
9
Soft tissue balancing in total shoulder replacement.
Curr Rev Musculoskelet Med. 2014 Mar;7(1):16-21. doi: 10.1007/s12178-013-9195-6.

本文引用的文献

1
Symptomatic glenoid loosening complicating total shoulder arthroplasty.
HSS J. 2010 Feb;6(1):52-6. doi: 10.1007/s11420-009-9148-1. Epub 2010 Jan 15.
2
Mid-term results of a metal-backed glenoid component in total shoulder replacement.
J Bone Joint Surg Br. 2010 Oct;92(10):1410-5. doi: 10.1302/0301-620X.92B10.23578.
3
Bone presence between the central peg's radial fins of a partially cemented pegged all poly glenoid component suggest few radiolucencies.
J Shoulder Elbow Surg. 2011 Mar;20(2):315-21. doi: 10.1016/j.jse.2010.05.025. Epub 2010 Sep 21.
4
Fixation of the glenoid component in total shoulder arthroplasty: what is "modern cementing technique?".
J Shoulder Elbow Surg. 2010 Dec;19(8):1129-36. doi: 10.1016/j.jse.2010.07.010. Epub 2010 Aug 30.
5
Clinical and radiographic analysis of a partially cemented glenoid implant: five-year minimum follow-up.
J Shoulder Elbow Surg. 2010 Oct;19(7):1091-7. doi: 10.1016/j.jse.2009.12.022. Epub 2010 Apr 9.
6
Mid-term survivorship analysis of a shoulder replacement with a keeled glenoid and a modern cementing technique.
J Bone Joint Surg Br. 2010 Mar;92(3):387-92. doi: 10.1302/0301-620X.92B3.23073.
7
The metal-backed glenoid component in rheumatoid disease: eight- to fourteen-year follow-up.
J Shoulder Elbow Surg. 2010 Jul;19(5):749-56. doi: 10.1016/j.jse.2009.11.005. Epub 2010 Mar 2.
8
Radiographic and histopathologic analysis of osteolysis after total shoulder arthroplasty.
J Shoulder Elbow Surg. 2010 Jun;19(4):588-95. doi: 10.1016/j.jse.2009.09.012. Epub 2009 Dec 29.
10
The glenoid in shoulder arthroplasty.
J Shoulder Elbow Surg. 2009 Sep-Oct;18(5):819-33. doi: 10.1016/j.jse.2009.05.008. Epub 2009 Jul 1.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验