Twelve patients were treated with didox, a new ribonucleotide reductase inhibitor, by 36 h infusion. The maximum tolerated dose was 6 g m-2, above which dose-limiting hepatic toxicity was observed. Patient tolerance was significantly better using the 36 h infusion compared to patients receiving the drug by a 30 min infusion; in particular, there were no reports of nausea or vomiting. No responses were seen in these patients. Detailed pharmacokinetics were performed at 6 g m-2 comparing the 36 h and 30 min infusions in four patients. Parent drug AUC values were lower for the 36 h infusion, 67.8 micrograms ml-1 h-1 compared to 232 micrograms ml-1 h-1 for the 30 min infusion. AUC values for the 3-hydroxy metabolite were much higher following the 36 h infusion: 55.4 compared to 18.6 micrograms ml-1 h-1. In contrast, the amide metabolite was not detected following the 36 h infusion, but AUC values of 23 micrograms ml-1 h-1 were seen after the 30 min infusion. The mean peak plasma level was 72 micrograms ml-1 following 6 g m-2 given by a 30 min infusion compared to 2.8 micrograms ml-1 following the prolonged infusion. Clearance was higher following the 36 h infusion: 97.6 versus 24.4 l h-1.

摘要

12名患者接受了新型核糖核苷酸还原酶抑制剂双多西(didox)治疗,采用36小时静脉输注。最大耐受剂量为6 g/m²,超过此剂量会出现剂量限制性肝毒性。与接受30分钟静脉输注该药的患者相比,采用36小时静脉输注时患者耐受性明显更好;尤其是未出现恶心或呕吐的报告。这些患者均未出现反应。对4名患者以6 g/m²剂量分别采用36小时和30分钟静脉输注进行了详细的药代动力学研究。36小时静脉输注时母体药物的AUC值较低,为67.8μg/ml·h⁻¹,而30分钟静脉输注时为232μg/ml·h⁻¹。36小时静脉输注后3 - 羟基代谢物的AUC值高得多:分别为55.4和18.6μg/ml·h⁻¹。相比之下,36小时静脉输注后未检测到酰胺代谢物,但30分钟静脉输注后AUC值为23μg/ml·h⁻¹。30分钟静脉输注给予6 g/m²后平均血浆峰浓度为72μg/ml,而长时间静脉输注后为2.8μg/ml。36小时静脉输注后的清除率更高:分别为97.6和24.4 l/h。

相似文献

引用本文的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验