Suppr超能文献

助听器部件导致的耳部损伤。

Ear injuries caused by parts of hearing aid.

作者信息

Zivic Ljubica, Zivic Danijela

机构信息

Otorhynolaringological Clinic of the Clinical Center of Kragujevac, Serbia.

出版信息

Med Glas (Zenica). 2011 Aug;8(2):287-9.

Abstract

This paper presents two cases of ear injuries caused by parts of hearing aids -a five-year old girl whose tympanic membrane was ruptured by a metal part of the earmold, and a patient with injury and inflammation of outer auditory channel caused by parts of a channel hearing aid. Aid amplifier could serve its purpose only if it is applied and handled with direct coordination with an ORL specialist.