Suppr超能文献

经 Visian 散光矫正型 ICL 与虹膜固定型 TICL 植入术后患者结局的比较。

Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens.

机构信息

Department of Ophthalmology, The Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea.

出版信息

Eye (Lond). 2011 Nov;25(11):1409-17. doi: 10.1038/eye.2011.176. Epub 2011 Aug 19.

Abstract

PURPOSE

We compared visual and refractive outcomes after implantation of Visian toric implantable collamer lenses (toric ICLs) and iris-fixated toric pIOLs (toric Artisans).

PATIENTS AND METHODS

A comparative retrospective analysis was performed. Toric ICLs were implanted into 30 eyes of 18 patients, and toric Artisans into 31 eyes of 22 recipients. We measured the logarithms of the minimum angle of resolution of uncorrected visual acuity (logMAR UCVA), logMAR of best spectacle-corrected corrected VA (logMAR BSCVA), MR, SE, and astigmatism (by the power vector method) before surgery and 1, 3, and 6 months thereafter. Differences between patients receiving each type of lens were compared by using a mixed model of repeated measures.

RESULTS

Visual improvements were evident after operation in both groups. By comparing the attempted to the achieved SE values, we were able to confirm that correction of refractive error was similar in both groups. However, the logMAR UCVA was significantly higher in the toric ICL group at all postoperative time points. Although manifest cylinder power and astigmatism (calculated by using the power vector method) gradually decreased in the toric ICL group, cylinder power 1 month postoperatively increased from -2.62 to -2.75 D; astigmatism was also increased at this time in the toric Artisan group.

CONCLUSION

The two tested toric pIOLs were similar in terms of the ability to correct refractive error, as assessed 3 months postoperatively. However toric ICLs corrected astigmatism more rapidly and safely. Notably, the large difference in astigmatism level between the two groups 1 month postoperatively indicates that toric ICLs are more effective when used to correct astigmatism.

摘要

目的

我们比较了 Visian 散光可植入性 Collamer 透镜(Toric ICL)和虹膜固定散光人工晶状体(Toric Artisans)植入术后的视力和屈光结果。

患者和方法

进行了一项比较性回顾性分析。将 Toric ICL 植入 18 名患者的 30 只眼中,将 Toric Artisans 植入 22 名受术者的 31 只眼中。我们测量了术前、术后 1、3 和 6 个月时未矫正视力的最小分辨角对数(logMAR UCVA)、最佳矫正视力的最佳矫正视力的对数(logMAR BSCVA)、等效球镜(MR)、SE 和散光(采用矢量法)。使用重复测量混合模型比较两种类型镜片的患者差异。

结果

两组患者术后视力均明显改善。通过比较目标 SE 值和实际 SE 值,我们能够确认两组的屈光不正矫正效果相似。然而,Toric ICL 组在所有术后时间点的 logMAR UCVA 均显著更高。尽管 Toric ICL 组的明视柱镜力和散光(采用矢量法计算)逐渐降低,但术后 1 个月时柱镜力从-2.62 增加至-2.75 D;此时 Toric Artisan 组的散光也增加了。

结论

在术后 3 个月评估时,两种测试的 Toric pIOL 在矫正屈光不正的能力方面相似。然而,Toric ICL 矫正散光更快且更安全。值得注意的是,术后 1 个月两组之间散光水平的巨大差异表明,Toric ICL 在矫正散光方面更有效。

相似文献

7
Artisan phakic intraocular lens in patients with keratoconus.圆锥角膜患者使用的个性化有晶状体眼人工晶状体
J Refract Surg. 2009 Sep;25(9):759-64. doi: 10.3928/1081597X-20090813-01. Epub 2009 Sep 11.

引用本文的文献

本文引用的文献

2
Assessment and statistics of surgically induced astigmatism.
Acta Ophthalmol. 2008 May;86 Suppl 1:5-28. doi: 10.1111/j.1755-3768.2008.01234.x.
10
Surgical correction of high degrees of astigmatism with a phakic toric-iris claw intraocular lens.
Int Ophthalmol Clin. 2003 Summer;43(3):171-81. doi: 10.1097/00004397-200343030-00016.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验