Department of Cardiac Surgery, Centre Chirurgical Marie Lannelongue, Le Plessis-Robinson, France.
Ann Thorac Surg. 2011 Sep;92(3):e49-50. doi: 10.1016/j.athoracsur.2011.03.110.
We describe off-pump wrapping of the ascending aorta in 3 high-risk patients with acute type A aortic dissection when the primary intimal tear was not located in the ascending aorta and in the absence of aortic insufficiency. A Teflon plaque (Bard Inc, Murray Hill, NJ) was tailored to tightly wrap the aorta from the coronary ostia to the innominate artery. The mean age of the patients was 80.3 years. All patients were at high risk for conventional surgery. A postoperative computed tomographic scan showed a reapplication of the intimal flap and containment of the false lumen in the reinforced ascending aorta in all patients.
我们描述了 3 例高危急性 A 型主动脉夹层患者在主撕裂口不在升主动脉且无主动脉瓣关闭不全时采用非体外循环包裹升主动脉的方法。将特氟隆斑块(Bard Inc,Murray Hill,NJ)裁剪为紧密包裹从冠状动脉开口到无名动脉的主动脉。患者的平均年龄为 80.3 岁。所有患者均有行传统手术的高风险。所有患者的术后 CT 扫描显示内膜瓣重新覆盖和强化升主动脉内假腔的封闭。