Suppr超能文献

缓冲液和牛奶中超声空化处理对阪崎克罗诺杆菌的灭活作用。

Inactivation of Cronobacter sakazakii by manothermosonication in buffer and milk.

机构信息

Tecnología de los Alimentos, Facultad de Veterinaria, Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.

出版信息

Int J Food Microbiol. 2011 Nov 15;151(1):21-8. doi: 10.1016/j.ijfoodmicro.2011.07.035. Epub 2011 Aug 4.

Abstract

The inactivation of Cronobacter sakazakii by heat and ultrasound treatments under pressure at different temperatures [manosonication (MS) and manothermosonication (MTS)] was studied in citrate-phosphate pH 7.0 buffer and rehydrated powdered milk. The inactivation rate was an exponential function of the treatment time for MS/MTS treatments (35-68 °C; 200 kPa of pressure; 117 μm of amplitude of ultrasonic waves) in both media, and for thermal treatments alone when buffer was used as heating media. Survival curves of C. sakazakii during heating in milk had a concave downward profile. Up to 50 °C, the lethality of ultrasound under pressure treatments was independent of the treatment temperature in both media. At temperatures greater than 64 °C in buffer and 68 °C in milk, the inactivating effect of MTS was equivalent to that of the thermal treatments alone at the same temperature. Between 50 and 64 ºC for buffer and 50 and 68 °C for milk, the lethality of MTS was the result of a synergistic effect, where the total lethal effect was higher than the lethal effect of heat added to that of ultrasound under pressure at room temperature. The maximum synergism was found at 60 °C in buffer and at 56 °C in milk. A heat treatment of 12 min (60 °C) or 4 min of an ultrasound under pressure at room temperature treatment (35 °C; 200 kPa; 117 μm) would be necessary to guarantee the death of 99.99% of C. sakazakii cells suspended in milk. The same level of C. sakazakii inactivation can be achieved with 1.8 min of a MTS treatment (60 °C; 200 kPa; 117 μm). Damaged cells were detected after heat treatments and after ultrasound under pressure treatments at lethal but not at non-lethal temperatures.

摘要

在不同温度下(手振超声处理 [MS] 和手动热声处理 [MTS]),在柠檬酸磷酸盐 pH 值 7.0 缓冲液和复水的奶粉中,研究了克罗诺杆菌的热和超声处理灭活情况。在这两种介质中,MS/MTS 处理(35-68°C;200 kPa 压力;117 µm 超声波振幅)的处理时间与失效率呈指数关系,而在缓冲液作为加热介质时,单独进行热处理也是如此。在牛奶中加热时,C. sakazakii 的存活曲线呈凹向下的形状。在 50°C 以下,两种介质中,压力下超声的致死性独立于处理温度。在缓冲液中温度大于 64°C 和牛奶中温度大于 68°C 时,MTS 的灭活效果与相同温度下的单独热处理相当。在缓冲液中温度为 50-64°C 和牛奶中温度为 50-68°C 之间,MTS 的致死性是协同作用的结果,总致死效果高于室温下热和压力下超声的致死效果之和。在缓冲液中最高协同作用出现在 60°C,在牛奶中最高协同作用出现在 56°C。需要 12 分钟(60°C)的热处理或 4 分钟的室温下超声处理(35°C;200 kPa;117 µm)才能保证悬浮在牛奶中的 99.99%的 C. sakazakii 细胞死亡。MTS 处理(60°C;200 kPa;117 µm)1.8 分钟即可达到相同水平的 C. sakazakii 灭活。在致死但非非致死温度下,热处理和超声处理后都检测到了受损细胞。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验