局限性容积锥形束 CT 在检测根尖周骨丧失中的诊断准确性:360°扫描与 180°扫描比较。

Diagnostic accuracy of limited-volume cone-beam computed tomography in the detection of periapical bone loss: 360° scans versus 180° scans.

机构信息

Department of Conservative Dentistry, Dental Institute, King's College London, London, UK.

出版信息

Int Endod J. 2011 Dec;44(12):1118-27. doi: 10.1111/j.1365-2591.2011.01930.x. Epub 2011 Sep 5.

Abstract

AIM

To investigate the effect of reducing limited-volume cone-beam computed tomographs arc of rotation from 360° to 180° on the ability to diagnose small, artificially created apical lesions.

METHODOLOGY

Small, artificial apical bone lesions were prepared with a bur in the apical region of the distal root of ten mandibular first molars, in human dry mandibles. The jaws were scanned in a fixed position with limited-volume CBCT making a 360° and 180° arc of rotation, before and after each periapical lesion had been created. A 4 × 4 cm field of view was used at 90 kV, with a current of 4 mA. Ten examiners blinded to the scan parameters and controls scored the presence/absence of bone lesions. Intra-examiner reliability was determined after 2 weeks, reviewing half the data set. Statistical analyses with paired t-tests determined the diagnostic accuracy of the two modalities (360° vs. 180°) in terms of sensitivity, specificity, receiver operating characteristic area under the curve, positive predictive values and negative predictive values.

RESULTS

The mean values for sensitivity of the 360° and 180° scans were 0.91 and 0.89, respectively; their mean specificities were 0.73. No significant differences were reflected in the statistical analyses.

CONCLUSIONS

Both 360° and 180° cone-beam computed tomography scans yielded similar accuracy in the detection of artificial bone lesions. The use of 180° scans might be advisable to reduce the radiation dose to the patient in line with the ICRP guidance to use as low a dosage as reasonably achievable.

摘要

目的

研究将容积锥形束 CT 旋转弧从 360°减少到 180°对诊断小的、人为造成的根尖病变的能力的影响。

方法

在人类干燥下颌骨的下颌第一磨牙远中根根尖区,用钻头制备小的人工根尖骨病变。在每个根尖病变形成之前和之后,在下颌骨固定位置使用容积锥形束 CT 进行 360°和 180°旋转扫描。使用 90 kV 的 4×4 cm 视野,电流为 4 mA。10 名检查者对扫描参数和对照组进行了盲法检查,以评估骨病变的存在/缺失。在 2 周后,通过回顾一半数据集来确定内部检查者的可靠性。使用配对 t 检验进行统计学分析,以确定两种模式(360°与 180°)在灵敏度、特异性、受试者工作特征曲线下面积、阳性预测值和阴性预测值方面的诊断准确性。

结果

360°和 180°扫描的平均灵敏度值分别为 0.91 和 0.89,平均特异性值分别为 0.73。统计分析没有反映出显著差异。

结论

360°和 180°锥形束 CT 扫描在检测人工骨病变方面具有相似的准确性。为了符合 ICRP 的指导方针,即使用尽可能低的剂量,使用 180°扫描可能是明智的,以减少患者的辐射剂量。