Department of Chemistry and Polymer Science, Stellenbosch University, Matieland, South Africa.
Anal Chim Acta. 2011 Oct 17;704(1-2):154-61. doi: 10.1016/j.aca.2011.07.037. Epub 2011 Jul 28.
A robust reversed phase ion-pairing RP-HPLC method has been developed for the unambiguous speciation and quantification of all possible homoleptic and heteroleptic octahedral platinum(IV) PtCl(6-n)Br(n) (n=0-6) as well as the corresponding platinum(II) PtCl(4-n)Br(n) (n=0-4) complex anions using UV/Vis detection. High resolution (195)Pt NMR in more concentrated solutions of these Pt(II/IV) complexes (≥50 mM) served to validate the chromatographic peak assignments, particularly in the case of the possible stereoisomers of Pt(II/IV) complex anions. By means of IP-RP-HPLC coupled to ICP-MS or ICP-OES it is possible to accurately determine the relative concentrations of all possible Pt(II/IV) species in these solutions, which allows for the accurate determination of the photometric characteristics (λ(max) and ɛ) of all the species in this series, by recording of the UV/Vis absorption spectra of all eluted species, using photo-diode array, and quantification with ICP-MS or ICP-OES. With this method it is readily possible to separate and estimate the concentrations of the various stereoisomers which are present in these solutions at sub-millimolar concentrations, such as cis- and trans-PtCl(4)Br(2), fac- and mer-PtCl(3)Br(3) and cis- and trans-PtCl(2)Br(4) for Pt(IV), and cis- and trans-PtCl(2)Br(2) in the case of Pt(II). All mixed halide Pt(II) and Pt(IV) species can be separated and quantified in a single IP-RP-HPLC experiment, using the newly obtained photometric molar absorptivities, ɛ, determined herein at given wavelengths.
已开发出一种稳健的反相离子对 RP-HPLC 方法,用于明确区分和定量所有可能的同核和异核八面体铂(IV)[PtCl(6-n)Br(n)]^(2-)(n=0-6)以及相应的铂(II)[PtCl(4-n)Br(n)]^(2-)(n=0-4)络合阴离子,使用 UV/Vis 检测。在这些 Pt(II/IV) 络合物的更浓溶液(≥50mM)中进行高分辨率(195)Pt NMR 分析有助于验证色谱峰分配,特别是对于 Pt(II/IV) 络合阴离子的可能立体异构体的情况。通过 IP-RP-HPLC 与 ICP-MS 或 ICP-OES 耦合,可以准确确定这些溶液中所有可能 Pt(II/IV) 物种的相对浓度,这允许通过记录所有洗脱物种的 UV/Vis 吸收光谱,使用光电二极管阵列,以及使用 ICP-MS 或 ICP-OES 进行定量,准确确定该系列中所有物种的光度特性(λ(max)和ε)。使用该方法,可以轻松分离和估计各种立体异构体的浓度,这些异构体以亚毫摩尔浓度存在于这些溶液中,例如顺式和反式-[PtCl(4)Br(2)]^(2-)、fac-和 mer-[PtCl(3)Br(3)]^(2-)和 cis-和 trans-[PtCl(2)Br(4)]^(2-)对于 Pt(IV),以及 Pt(II)情况下的 cis-和 trans-[PtCl(2)Br(2)]^(2-)。所有混合卤化物 Pt(II)和 Pt(IV) 物种都可以在单个 IP-RP-HPLC 实验中分离和定量,使用在此处给定波长下确定的新获得的光学生摩尔吸光度ε。