Abstract

INTRODUCTION

Ipsilateral rotational penetrating autokeratoplasty technique may be an alternative to minimize the problem of long waiting lists for transplantation due to keratoconus.

PURPOSE

To report the visual outcomes in keratoconus patients after ipsilateral rotational penetrating autokeratoplasty technique (IRPAK) associated with a crescent-shape resection of 0.5 mm of the inferior cornea.

METHODS

According to a prospective, longitudinal, interventional, analytic study, the authors investigated the visual results of 15 patients (18 eyes) with keratoconus, who underwent an ipsilateral rotational penetrating autokeratoplasty, by two coincident trepanations superiorly and with a difference of 0.5 mm inferiorly. After resection of this corneal crescent, a 180° rotation of the corneal disk was performed, which was fixed with 24 sutures diametrically opposed. The patients were followed-up for a period of 24 months.

RESULTS

Comparing data of the first and second postoperative years to preoperative data, there were: significant improvements in visual acuity, vision lines and spherical equivalent; reduction of topographic astigmatism and maximum and mean corneal curvatures. There was also a decrease in corneal thickness associated to a reduction of corneal endothelial cell count.

CONCLUSION

There was an improvement of ophthalmologic parameters 6, 12 and 24 months after ipsilateral rotational penetrating autokeratoplasty associated with a crescent-shape resection of 0.5 mm of the inferior cornea, but along the follow-up there was reduction of visual acuity with increased astigmatism.

摘要

引言

同侧旋转穿透性自体角膜移植术可能是一种解决圆锥角膜导致移植等待名单过长问题的替代方法。

目的

报告圆锥角膜患者在接受同侧旋转穿透性自体角膜移植术(IRPAK)并联合下方角膜0.5mm新月形切除术后的视力结果。

方法

根据一项前瞻性、纵向、干预性、分析性研究,作者调查了15例(18只眼)圆锥角膜患者的视力结果,这些患者接受了同侧旋转穿透性自体角膜移植术,上方采用两个重合的环钻,下方相差0.5mm。切除该角膜新月形组织后,将角膜盘进行180°旋转,并用24根对侧缝线固定。对患者进行了24个月的随访。

结果

将术后第一年和第二年的数据与术前数据进行比较,发现:视力、视轴和球镜等效度有显著改善;地形图散光、最大和平均角膜曲率降低。角膜厚度也有所下降,同时角膜内皮细胞计数减少。

结论

在与下方角膜0.5mm新月形切除相关的同侧旋转穿透性自体角膜移植术后6、12和24个月,眼科参数有所改善,但在随访过程中,视力下降,散光增加。