[Establishment and evaluation of a modified plasma protamine paracoagulation test].

作者信息

Tang Xu-hua, Li Qiang, Lin Wen-hao, Fu Lin, Wang Qiang, Xie Xiao-ping, Zhang Yu-ming

机构信息

173 Clinic, 421 Hospital of PLA, Huizhou 516008, China.

出版信息

Nan Fang Yi Ke Da Xue Xue Bao. 2011 Sep;31(9):1626-8.

Abstract

OBJECTIVE

To establish a modified plasma protamine paracoagulation test.

METHODS

Plasma protamine paracoagulation, modified plasma protamine paracoagulation and D-dimer (D-D) tests were performed for the plasma samples collected from 98 cases of disseminated intravascular coagulation (DIC) and 156 normal subjects. The sensitivity and specificity of the 3 tests were analyzed. The plasma samples from 8 cases of suspected myocardial infarction were detected using modified plasma protamine paracoagulation for diagnostic purpose.

RESULTS

The sensitivity of plasma protamine paracoagulation, modified plasma protamine paracoagulation and D-D tests was 16.33%, 88.76% and 77.56%, and the specificity was 100%, 88.46% and 97.44%, respectively. Positive results occurred earlier in modified plasma protamine paracoagulation test than in plasma protamine paracoagulation and D-D tests in 5 cases of myocardial infarction.

CONCLUSION

The modified plasma protamine paracoagulation test has a higher sensitivity than plasma protamine paracoagulation test and a higher specificity than D-D test, and can be helpful in early diagnosis of thrombosis and fibrinolysis.