Suppr超能文献

使用 F-18 氟代脱氧葡萄糖正电子发射断层扫描来区分全髋关节置换术后患者的感染性松动和无菌性松动。

Use of F-18 fluoride PET to differentiate septic from aseptic loosening in total hip arthroplasty patients.

机构信息

Department of Orthopaedic Surgery, Yokohama City University, School of Medicine, Yokohama, Japan.

出版信息

Clin Nucl Med. 2011 Nov;36(11):e156-61. doi: 10.1097/RLU.0b013e3182291ae7.

Abstract

PURPOSE

The preoperative differentiation of aseptic and septic loosening following a total hip arthroplasty (THA) remains a challenging issue for clinicians to which several molecular imaging techniques have been applied. In our current study, we used F-18 fluoride positron emission tomography (PET) to evaluate THA cases with stable, septic or septic loosened implants to assess the possibility of differentiating these clinical settings using a novel uptake-type classification approach.

MATERIALS AND METHODS

A total of 65 joints were enrolled in this prospective study comprising 27 asymptomatic stable hips (control group), 11 painful hips conservatively treated after THA due to a suspicion of loosening, and 27 painful hips surgically treated after THA. PET imaging was classified into 3 types according to the uptake pattern. The maximum standardized uptake value (SUVmax) was then measured for each joint. A final diagnosis was made via tissue examinations of surgically treated cases, and by serological and radiographic findings in conservatively treated cases.

RESULTS

There were significant differences found between the SUVmax values for the aseptic and septic loosening THA cases. In the diagnosis of infection with type 3 pattern, the sensitivity and specificity were measured at 0.95 and 0.98 for all cases, and 0.95 and 0.88 for surgically treated cases, respectively.

CONCLUSIONS

The results of our current study demonstrate that F-18 fluoride PET has considerable potential as a method for differentiating septic from aseptic loosening following a THA. The type classification of the uptake pattern can be performed relatively simply, and quantifications using the SUVmax values can then provide an objective evaluation.

摘要

目的

全髋关节置换术后(THA)无菌性和感染性松动的术前鉴别仍然是临床医生面临的一个挑战,为此已经应用了多种分子影像学技术。在我们当前的研究中,我们使用 F-18 氟正电子发射断层扫描(PET)来评估具有稳定、感染或感染性松动植入物的 THA 病例,以评估使用新型摄取型分类方法来区分这些临床情况的可能性。

材料和方法

这项前瞻性研究共纳入 65 个关节,包括 27 个无症状稳定的髋关节(对照组)、11 个因怀疑松动而经 THA 保守治疗的疼痛髋关节,以及 27 个因 THA 而经手术治疗的疼痛髋关节。根据摄取模式,将 PET 成像分为 3 种类型。然后测量每个关节的最大标准化摄取值(SUVmax)。通过手术治疗病例的组织检查和保守治疗病例的血清学和影像学检查做出最终诊断。

结果

在无菌性和感染性 THA 松动病例的 SUVmax 值之间发现了显著差异。在诊断 3 型模式感染时,所有病例的灵敏度和特异性分别为 0.95 和 0.98,手术治疗病例的灵敏度和特异性分别为 0.95 和 0.88。

结论

我们当前研究的结果表明,F-18 氟化物 PET 具有很大的潜力,可以作为区分 THA 后无菌性和感染性松动的一种方法。摄取模式的类型分类可以相对简单地进行,然后使用 SUVmax 值进行定量可以提供客观评估。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验