OBJECTIVE

The Outreach distal access catheter (DAC; Concentric Medical, Mountain View, California, USA) has been designed to assist the Merci device (Concentric Medical) with clot retrieval in the setting of acute stroke. Its application for coil embolization of intracranial aneurysms was investigated.

METHODS

Between December 2008 and January 2010, 150 aneurysms were treated with endovascular methods. In 18 cases of small aneurysms and/or increased parent vessel tortuosity, the DAC was used for additional support. Merits and complications related to the use of this catheter are reviewed.

RESULTS

The mean aneurysm size was 7.1 mm (range 3.5-25). In each case, the DAC was used as an intracranial platform catheter in close proximity to the target aneurysm. This catheter (outer diameter 3.9 or 4.3 French) increased the stability and reduced the redundancy of the microcatheter. As a result, handling and control of the microcatheter were improved. In three cases, the coiling procedure could not be completed because of difficulties not related to the DAC. Aneurysms in the remaining patients were treated successfully with complete (n=12) or near complete (n=3) angiographic occlusion.

CONCLUSION

For smaller or distal intracranial aneurysms with difficult access, use of the DAC as an additional platform in close proximity to the target aneurysm subjectively enhanced microcatheter control and safety.

摘要

目的

外联远端接入导管(DAC;加利福尼亚州山景城同心医疗公司制造)旨在协助 Merci 装置(同心医疗公司)在急性中风时进行血栓清除。研究了其在颅内动脉瘤线圈栓塞中的应用。

方法

2008 年 12 月至 2010 年 1 月期间,采用血管内方法治疗了 150 个动脉瘤。在 18 例小动脉瘤和/或增加的母血管扭曲的情况下,使用 DAC 提供额外的支持。回顾了与使用这种导管相关的优点和并发症。

结果

平均动脉瘤大小为 7.1mm(范围 3.5-25)。在每种情况下,DAC 都用作靠近目标动脉瘤的颅内平台导管。这种导管(外径 3.9 或 4.3 法国)增加了微导管的稳定性并减少了其冗余。结果,微导管的处理和控制得到了改善。在 3 例病例中,由于与 DAC 无关的困难,无法完成线圈栓塞程序。其余患者的动脉瘤均成功治疗,完全(n=12)或接近完全(n=3)血管造影闭塞。

结论

对于较小或靠近颅内的难以进入的动脉瘤,将 DAC 用作靠近目标动脉瘤的附加平台,可主观地增强微导管的控制和安全性。