Abstract

Atropine is used in the daily clinical practice for the treatment of poisonings caused by anticholinesterase pesticides, due to its sympathomimetic action. The investigation of the cause of the adverse effects that appear during atropine administration showed the necessity for the development and validation of a simple, rapid, sensitive, and specific method for the determination of atropine levels in serum samples. The developed method includes liquid-liquid extraction with ethyl acetate: dichloromethane (3:1, v/v) and derivatization using N,O-bis(trimethylsilyl)-trifluoracetamide (BSTFA) with 1% trimethylchlorsilane (TMCS) in acetonitrile environment. The method was found to be selective, linear, accurate, and precise according to international guidelines. The recovery was higher than 85.9%, the limit of quantification was 2.00 ng/ml, and the calibration curve was linear within the range of 2.00-500 ng/ml (R(2)  ≥ 0.992). Accuracy and precision were also calculated and were found to be less than 5.2 and 8.7%, respectively. The developed method was applied in a real case of accidental poisoning with chlorpyrifos in order to determine the atropine serum levels of the patient. The proposed method proved to be useful for the investigation of adverse effects that appear during atropine treatment of patients poisoned by anticholinesterase pesticides and it can also be used for the investigation of poisonings caused after consumption of atropine containing plants.

摘要

在日常临床实践中,由于阿托品具有拟交感神经作用,因此被用于治疗有机磷杀虫剂中毒。阿托品给药后出现不良反应的原因调查表明,有必要开发和验证一种简单、快速、灵敏、特异的方法,用于测定血清样本中的阿托品浓度。所开发的方法包括用乙酸乙酯:二氯甲烷(3:1,v/v)进行液液萃取,以及在乙腈环境中使用 N,O-双(三甲基硅基)-三氟乙酰胺(BSTFA)与 1%三甲基氯硅烷(TMCS)进行衍生化。根据国际指南,该方法被证明具有选择性、线性、准确性和精密度。回收率高于 85.9%,定量限为 2.00ng/ml,校准曲线在 2.00-500ng/ml 范围内呈线性(R²≥0.992)。准确度和精密度也进行了计算,分别小于 5.2%和 8.7%。该方法应用于氯吡硫磷意外中毒的实际案例中,以测定患者的血清阿托品浓度。该方法被证明对研究阿托品治疗有机磷杀虫剂中毒患者出现的不良反应有用,也可用于研究因摄入含有阿托品的植物而引起的中毒。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验