Azarsina M, Kasraei Sh, Masoum T, Khamverdi Z
Post Graduate Student, Department of Operative Dentistry, Faculty of Dentistry, Hamadan University of Medical Sciences, Hamadan, Iran.
J Dent (Tehran). 2011 Winter;8(1):33-8. Epub 2011 Mar 31.
This study evaluated the effect of surface polishing on mercury release from dental amalgam after treatment with 16% carbamide peroxide gel.
Ninety-six samples from two different amalgam brands were prepared in truncated cone-shaped PVC polymer molds with an external surface area of 195 mm(2). Half of the specimens were polished with green and red rubber, a brush and tin oxide paste at low speed. Samples were treated with 16% carbamide peroxide gel in tubes containing 3 mL of carbamide peroxide gel and 0.1 mL of distilled water for 14 and 28 hours. Subsequently, carbamide peroxide gel on the sample surfaces was rinsed away with 7.0 mL of distilled water until the volume of each tube increased to 10 mL. The mercury level of each solution was measured using the VAV-440 mercury analyzer system. Considering the surface area of each amalgam disc, mercury amounts were calculated in μg/mm(2). Data were analyzed using two-way ANOVA.
There were significant differences between the mean levels of mercury release from polished vs. unpolished amalgam surfaces after treatment with 16% carbamide peroxide. Increasing the storage time from 14 to 28 hours did not result in significant changes in the amount of mercury release. There was no significant interaction effect between amalgam surface polish and storage time statistically.
Polished amalgam restorations release less mercury after treatment with carbamide peroxide bleaching gel in comparison with unpolished amalgam restorations.
本研究评估了用16%过氧化脲凝胶处理后,表面抛光对牙科汞合金汞释放的影响。
从两种不同品牌的汞合金中制备九十六个样本,样本置于截头圆锥形聚氯乙烯聚合物模具中,外表面积为195平方毫米。一半样本用绿色和红色橡胶、刷子及低速的氧化锡糊剂进行抛光。样本在装有3毫升过氧化脲凝胶和0.1毫升蒸馏水的试管中用16%过氧化脲凝胶处理14小时和28小时。随后,用7.0毫升蒸馏水将样本表面的过氧化脲凝胶冲洗掉,直至每个试管的体积增至10毫升。使用VAV - 440汞分析仪系统测量每种溶液的汞含量。根据每个汞合金圆盘的表面积,以微克每平方毫米计算汞含量。数据采用双向方差分析进行分析。
用16%过氧化脲处理后,抛光与未抛光汞合金表面的平均汞释放水平之间存在显著差异。将储存时间从14小时增加到28小时,汞释放量未发生显著变化。汞合金表面抛光与储存时间之间在统计学上没有显著的交互作用。
与未抛光的汞合金修复体相比,抛光后的汞合金修复体在用过氧化脲漂白凝胶处理后释放的汞较少。