Ramírez Juan Fernando, Isaza Jésica Andrea, Mariaka Isabela, Vélez Jaime Andrés
National University of Colombia, Medellín, Colombia.
Prosthet Orthot Int. 2011 Dec;35(4):459-66. doi: 10.1177/0309364611420478. Epub 2011 Oct 17.
There is a relation between Hounsfield units obtained from computed tomography (CT) scans and bone density. The density of the bones can be used to establish its mechanical properties and therefore to assess the bone mechanical condition using CT images.
To identify the effect of the transfemoral amputation and the use of external lower limb prosthesis in the bone properties, by comparing Young's modulus.
Young's modulus comparison.
Comparison of bone density between the healthy femur and the amputated bone of 20 unilateral transfemoral amputees was done by generating three histograms of the Hounsfield units at different parts of the femur. The histograms were created based on images obtained by CT and the Hounsfield units were translated to Young's modulus to establish the comparison.
The results show a significant difference (p-value <0.05) between the mean value of Young's modulus of healthy and amputated bone.
There is clearly a direct association between the use of external prosthesis and the bone demineralization due the stress shielding phenomenon. The Young's modulus comparison using information from CT images can be a suitable tool to analyze the bone demineralization due to the use of exoprosthesis.