Suppr超能文献

聚乙烯髋臼衬垫在金属杯内的早期失败。

Early failure of a polyethylene acetabular liner cemented into a metal cup.

机构信息

Dalhousie University, Halifax, Nova Scotia, Canada.

出版信息

J Arthroplasty. 2012 May;27(5):820.e5-8. doi: 10.1016/j.arth.2011.09.009. Epub 2011 Oct 19.

Abstract

In 2002, a patient underwent revision total hip arthroplasty for polyethylene wear. The acetabular cup was well fixed, and it was decided to cement a new polyethylene liner into the existing cup. In 2006, the patient presented with inability to weight bear and easy subluxation of the hip. Revision surgery was performed, and all components were examined postoperatively. Investigation with microcomputed tomography revealed that the liner had plastically deformed at the superior pole resulting in the hip instability. The reasons for this are suspected to be related to the abducted nature of the original cup and an uneven cement mantle. This report suggests that cementation of polyethylene liners into metal cups has limitations and is not appropriate in all circumstances.

摘要

2002 年,一位患者因聚乙烯磨损而行翻修全髋关节置换术。髋臼杯固定良好,决定将新的聚乙烯衬垫粘接到现有杯内。2006 年,患者出现无法负重和髋关节易脱位的情况。行翻修手术,术后检查所有组件。微计算机断层扫描显示衬垫在上极发生塑性变形,导致髋关节不稳定。怀疑其原因与原始杯的外展角度和不均匀的水泥覆盖层有关。本报告表明,将聚乙烯衬垫粘接到金属杯内存在局限性,并非所有情况下都适用。